beautypg.com

Warning (gas models only), Electrical service specifications, Steam models only – American Dryer Corp. T30 User Manual

Page 18: Electrical service specifications gas models only

background image

18

JLA Limited

113429 - 9

Warning (Gas Models Only)

Dryers built for use with a voltage between 200
and 240 must verify the input voltage during

installation. If the nominal voltage is outside of the
medium tolerances shown on the diagram below, adjust

!

TERM

LINE VOLTAGE

50 Hz

60 Hz

HIGH

260
226

283
249

MED

239
208

260
230

LOW

217

189

236
208

NOTES ______________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

ELECTRICAL SERVICE SPECIFICATIONS

IMPORTANT:

NOTES: A.

B.


C.

208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify
exact voltage.

When fuses are used they must be dual element, time delay, current limiting,
class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying
either local and/or National Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.
For others, calculate/verify correct breaker size according to appliance amp
draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

CIRCUIT

BREAKER

60 Hz

50 Hz

T20

120

2

8.9

15

200

2

7.7

7.8

15

208

2

7.6

15

220

2

7.4

15

230

2

7.3

15

240

2

7.2

7.0

15

T30

120

2

10.3

15

200

2

8.7

8.8

15

208

2

8.4

15

220

2

8.1

8.1

15

230

2

7.4

15

240

2

7.7

7.0

15

T50

120

2

15.6

20

200

2

10.5

20

208

2

10.5

20

220

2

10.0

10.7

20

230

2

10.8

20

240

2

9.7

20

T75

120

2

15.6

20

200

2

10.5

20

208

2

10.5

20

220

2

10.0

10.7

20

230

2

10.8

20

240

2

9.7

20

Steam Models Only

7/15/08

the autotransformer, located
near the burner assembly.
To adjust the
autotransformer wiring,
place the red wire on the
appropriate tap (HIGH, MED,
LOW) of the
autotransformer. For
additional wiring details,
refer to the electrical
diagram located on the
inside of the control panel.

Electrical Service Specifications
Gas Models Only

7/15/08

ELECTRICAL SERVICE SPECIFICATIONS

IMPORTANT:

NOTES: A.

B.


C.

208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify
exact voltage.

When fuses are used they must be dual element, time delay, current limiting,
class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying
either local and/or National Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.
For others, calculate/verify correct breaker size according to appliance amp
draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

CIRCUIT

BREAKER

60 Hz

50 Hz

T30

120

2

9.3

15

208

2

6.2

6.0

15

220

2

5.6

5.5

15

230

2

5.4

15

240

2

5.1

15

T50

120

2

14.4

20

200

2

8.2

20

208

2

8.2

20

220

2

7.8

8.4

20

230

2

8.5

20

240

2

7.6

20

T75

120

2

14.4

20

200

2

8.2

20

208

2

8.2

20

220

2

7.8

8.4

20

230

2

8.5

20

240

2

7.6

20

This manual is related to the following products: