beautypg.com

HP Server Management Packs for Microsoft System Center Essentials User Manual

Page 79

background image

Event rules for HP ProLiant servers 79

Windows® Event ID

Storage server event description

Target class

1164

Drive array controller degraded

Storage (ProLiant SNMP)

1165

Drive array controller degraded

Storage (ProLiant SNMP)

1173

Fibre Channel tape controller degraded Storage (ProLiant SNMP)

1174

Fibre Channel tape library degraded

Storage (ProLiant SNMP)

1175

Fibre Channel tape library door
degraded

Storage (ProLiant SNMP)

1176

Fibre Channel tape drive degraded

Storage (ProLiant SNMP)

1177

Fibre Channel tape drive degraded

Storage (ProLiant SNMP)

1178

Fibre Channel tape drive degraded

Storage (ProLiant SNMP)

1179

External array controller degraded or

failed

Storage (ProLiant SNMP)

1180

Drive array tape library degraded

Storage (ProLiant SNMP)

1181

Drive array tape library door degraded Storage (ProLiant SNMP)

1182

Drive array tape drive degraded

Storage (ProLiant SNMP)

1183

Drive array tape drive degraded

Storage (ProLiant SNMP)

1184

Drive array tape drive degraded

Storage (ProLiant SNMP)

1185

Fibre Channel controller degraded

Storage (ProLiant SNMP)

1186

IDE ATA disk degraded

Storage (ProLiant SNMP)

1187

ATA RAID logical drive degraded

Storage (ProLiant SNMP)

1188

Storage system fan degraded

Storage (ProLiant SNMP)

1189

Storage system temperature degraded

Storage (ProLiant SNMP)

1190

Storage system power supply degraded Storage (ProLiant SNMP)

1192

SCSI tape drive failed

Storage (ProLiant SNMP)

1193

External tape drive degraded

Storage (ProLiant SNMP)

1194

External tape drive degraded

Storage (ProLiant SNMP)

1195

External tape drive degraded

Storage (ProLiant SNMP)

1196

Storage system recovery server

degraded

Storage (ProLiant SNMP)

1197

External tape library degraded

Storage (ProLiant SNMP)

1198

External tape library door degraded

Storage (ProLiant SNMP)

1199

Drive array controller degraded

Storage (ProLiant SNMP)

1201

Drive array spare drive degraded

Storage (ProLiant SNMP)

1202

Drive array physical drive degraded

Storage (ProLiant SNMP)

1203

Drive array physical drive degraded

Storage (ProLiant SNMP)

1204

Drive array accelerator degraded or
failed or battery failed

Storage (ProLiant SNMP)

1205

Drive array accelerator data degraded
or failed

Storage (ProLiant SNMP)

1206

Drive array accelerator degraded or
failed or battery degraded

Storage (ProLiant SNMP)

1207

Drive array tape library degraded

Storage (ProLiant SNMP)