American Power Conversion RS 1500 User Manual

American Power Conversion Tools

background image

CONNECT TVSS

Back-UPS

®

RS 1000

User’s Manual

Back-UPS

®

RS 1500

1

®

CONTENTS

RJ-45

USB

RJ-11

RJ-11

2

CONNECT BATTERY CARTRIDGE

4

CONNECT EQUIPMENT / POWER

Monitor

Printer or Scanner

FAX

External Disk or

CD / DVD Drive

10

INSTALL SOFTWARE ON

COMPUTER

There are four status indicators (lights) on the

front panel of the Back-UPS (On Line, On

Battery, Overload, and Replace Battery).

On Line (green) - is lit whenever utility

power is powering the Battery Backup

outlets.

On Battery (yellow) - is lit whenever the

battery of the Back-UPS is powering

equipment connected to the Battery

Backup Outlets.

Four Beeps Every 30 Seconds - this

alarm is sounded whenever the Back-UPS

is running On Battery. Consider saving

work in progress.

Overload (red) - is lit whenever power

demand has exceeded the capacity of the

Back-UPS.

Continuous Tone - this alarm is sounded

whenever the Battery Backup outlets are

overloaded.

Circuit Breaker - the circuit breaker button

located on the rear panel of the Back-UPS

will stick out if an overload condition forces

the Back-UPS to disconnect itself from

utility power. If the button sticks out,

disconnect non-essential equipment. Reset

the circuit breaker by pushing the button

inward.

Replace Battery (red) - is lit whenever the

battery is near the end of its useful life, or

if the battery is not connected (see above).

A battery that is near the end of its useful

life has insufficient run-time and should be

replaced.

Chirps for 1 Minute Every 5 Hours - this

alarm is sounded whenever the battery has

failed the automatic diagnostic test.

Continuous Beeping - this alarm is

sounded whenever a low battery condition

is reached. Battery run-time is very low.

Promptly save any work in progress and

exit all open applications. Shutdown the

operating system, computer and the Back-

UPS.

NOTE: Macintosh Users - for full USB

performance, use OS 9.22 or higher.

If Autoplay is not enabled on the computer,

proceed as follows:
1. On the computer desktop of the display,

double-click on My Computer.

2. Double-click on the CD-ROM drive icon

and follow the on-screen instructions.

11

GROUND

The Back-UPS features a transient

voltage surge-suppression (TVSS)

screw for connecting the ground lead

on additional surge suppression devices

such as network and data line surge

protectors.

Wall

Outlet

Modem/

Phone/Fax

TVSS GND

From Data Line

TVSS

Follow the

on-screen

instructions.

On Line

On Battery

Overload

Replace Battery

w

w

w.apc.com

®

STATUS INDICATORS AND ALARMS

SERVICE

If the Back-UPS arrived damaged, notify the

carrier.
If the Back-UPS requires service, do not

return it to the dealer. The following steps

should be taken:

1. Consult the Troubleshooting section to

eliminate common problems.

2. If the problem persists, go to http://

www.apc.com/support/.

3. If the problem still persists, contact APC

Technical Support.

4. Have the Back-UPS model number, serial

number and date of purchase available. Be

prepared to troubleshoot the problem with an

APC Technical Support representative. If

this is not successful, APC will issue a

Return Merchandise Authorization (RMA)

number and a shipping address.

7

To Computer USB

Port

CONNECT INTERFACE CABLE

Data Port

BR24BP Battery Pack

Computer

RJ-45

USB

For connection of APC’s optional

external 24-volt battery pack

(BR24BP) to the Back-UPS RS 1000

3

5

Phone Jack

Computer

Modem Port

CONNECT PHONE/MODEM/FAX

TVSS GND

Wall

Outlet

Wall

Outlet

Modem/

Phone/Fax

6

CONNECT 10/100 Base-T or VOIP

Network Jack

Computer

Network Port

Note: Allow the Back-UPS to charge for a

full eight (8) hours prior to use.
Press the front panel Power ON/OFF switch

and observe that the following events occur

after pressing and releasing the switch:

• The green On Line indicator flashes.
• The yellow On Battery indicator lights

while a Self-Test is being performed.

• When Self-Test has successfully

completed, only the green On Line

indicator will be lit.

• If the internal battery cartridge is not

connected (see Step 2 above), the green

On Line indicator and red Replace Battery

indicators will light. The Back-UPS will

also emit a chirping sound.

8

SWITCH ON THE BACK-UPS

9

ORIENTATION

10/100 Base-T

VOIP

✔ ✔

Computer

3

OPERATING ENVIRONMENT

32 - 104

o

F (0 - 40

o

C)

24 inches

60 cm

BATTERY

BACKUP

SURGE ONLY

OR

and Back-UPS RS 1500.

This manual is related to the following products: