Agilent Technologies J3972A User Manual
Page 48

Local Terminal Configuration
Using a Local Terminal
28
It requires the IP Address, Subnet Mask, and Default
Gateway IP Address fields. The following apply to Telemetry
ports:
z
HP OpenView can discover the interface
z
The interface is IP addressable
z
The interface responds to RMON-1
z
The interface will transmit all traps from the probe
z
The interface will transmit all extended RMON packets
sample from Monitor-only ports, Monitor/Transmit ports.
IP Address
Press
3
and enter the IP address for the probe. If the IP
address is
0.0.0.0
, the probe will transmit Bootp Requests
for configuration information (including IP address) over the
network. This does not apply to ports configured as Monitor-
Only.
Default Gateway
Press
4
and enter the default gateway IP address for the probe
IP Address
(optional).
Subnet Mask
Press
5
and enter the subnet mask for the probe.
Physical
Press
6
and select the physical connector. The menu only
Connector
shows the physical connectors that are available. You can use
the RJ-45 or AUI connector. If you select AUI, items 7 and 8
(Link Speed and Full/Half Duplex) are not available. AUI is
10MB/s half-duplex.
CAUTION
If you manually selected the Link Speed, be careful to configure it correctly. If
you configure the Link Speed for 100 MB/s and you connect the probe to a
10MB/s network, the probe will generate 100% utilization for that segment.
Link Speed
Press
7
and select the Link Speed as Auto Negotiate,
10MB/s, or 100MB/s. When you configure this parameter for
Auto Negotiate, the item 8 parameter (Full/Half Duplex) is
not available.