American Dryer Corp. Gas- DSI/Steam ML-82 II User Manual
Page 27

23
2. Technical Gas Data
a. Gas Specifications
b. Gas Connections
Inlet connection --- 1-inch N.P.T.
Inlet supply size --- 1-inch N.P.T. (minimum)
BTU/hr input ------ 270,000 (68,040 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12 inches
(29.9 mb) water column pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas
valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator
or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source
(L.P. tank) or an external regulator must be added to each dryer.
* Drill material size (D.M.S.) equivalents are as follows:
Natural Gas ........................... #23 = 0.154” (3.9116 mm).
Liquid Propane Gas .............. #41 = 0.096” (2.4384 mm).
T
YP E OF
G
AS
Natural
Liquid Propane (L.P.)
Manifold Pressure*
3.5 inches W.C.
8.7 mb
10.5 inches W.C.
26.1 mb
Inline Pressure
6.0 - 12.0 inches W.C.
14.92 - 29.9 mb
10.5 inches W.C.
26.1 mb
Shaded areas are stated in metric equivalents
* Measured at gas valve pressure tap when the gas valve is on.
T
YPE OF
G
AS
L.P.
Conversion Kit
Part
Number
MODEL
NUMBER
BTU
Per Hour
Rating
kcal/hr
Rating
Natural
Liquid Propane
Qty. D.M.S.*
Part
Number
Qty. D.M.S.*
Part
Number
MLG-82
270,000
68,040
4
#23
140856
4
#41
140811
882119
Shaded area is stated in metric equivalent