Technical specifications – Atmos Energy HE26 User Manual
Page 50

10. TECHNICAL SPECIFICATIONS
Appliance category
B13; B33; C13; C 33; C 43; C53; C63; C83
Gas inlet pressure
20 mbar
Suitable for gas
II
2
H
3
P
Technical data
InterSystem HE 26
CH
Heat power input (gross)*
kW
8.0 – 30.3
Heat power input (net)*
kW
7.2 – 27.3
Heat output at 80/60°C*
kW
7.0 – 26.2
Heat output at 50/30°C*
kW
7.7 – 26.8
Max. CH water pressure
bar
2.5 (see note 1)
CH operating pressure
bar
1 – 2 (see note 2)
Max. CH water temperature
°C
90
Other data
Gas consumption
m
3
/h
0.85 - 3.25
Electrical data
Mains voltage
V
230
Protection class
IP44 (B(.)=IP20)
Consumed power: full load
W
105
Consumed power: partial load
W
40
Consumed power: standby
W
2.4
Overall dimensions and weight
Height mm
810
Width mm
450
Depth mm
270
Weight kg
39
*The maximum CH power is set to 50% of the highest value at the factory (see Setting CH power).
Notes 1 - Safety discharge valve is 3 bar.
2 – Min pressure 1 bar ( expansion vessel pre-charge is 1 bar).
50