Reduced output, Ch does not reach the correct temperature – Atmos Energy HE26 User Manual
Page 45

8.5 Reduced output
Possible causes
Remedies
8.6 CH does not reach the correct temperature
Table 6. NTC resistances
NTC 12 kOhm
T [°C]
R[ohm]
T [°C]
R[ohm]
T [°C]
R[ohm]
-15 76020 25
12000 65
2752
-10
58880
30 9805
70 2337
-5 45950
35 8055
75 1994
0 36130
40 6653
80 1707
5 28600
45 5522
85 1467
10 22800
50 4609
90 1266
15 18300
55 3863
95 1096
20 14770
60 3253
100 952
1. Check appliance and flue system
At high speed, the power has decreased
Yes
by not more than 5%.
for pollution.
2. Clean appliance and flue system.
Possible causes
1. Check the setting and adjust if
Room thermostat settings not correct.
Yes
necessary: set to 0.1 A.
No
1. Raise the pump setting or replace
the pump.
1. Check for circulation: at least 2 or 3
radiators must be open.
1. Adjust the power,
see Setting maximum CH power.
1. Descale or flush the heat exchanger
on the CH side.
No heat transfer due to scaling or pollution
in the heat exchanger.
Yes
The boiler power is not set well
for the system.
Yes
No
No
No circulation in the system.
Yes
Pump does not run well.
Pump setting too low.
Yes
No
No
1. Raise the CH temperature,
Temperature set too low.
see CH operation.
Yes
2. Check the outside sensor for
short circuit: remedy this..
Remedies
45