Electrical connection – Alto-Shaam HFM-30 User Manual
Page 6

1.
An identification tag is permanently mounted
on the unit.
2.
If necessary, a proper receptacle or permanent
wiring for this unit must be installed by a
licensed electrician in accordance with
applicable local electrical codes.
3.
Plug the unit into a properly grounded
receptacle ONLY, positioning the unit so the
power supply cord is easily accessible in case
of an emergency. Arcing will occur when
connecting or disconnecting the unit unless
all controls are in the OFF position.
230V:
To prevent an electrical shock hazard
between the appliance and other appliances or
metal parts in close vicinity, an equalization-
bonding stud is provided. An equalization
bonding lead must be connected to this stud and
the other appliances / metal parts to provide
sufficient protection against potential difference.
The terminal is marked with the following
symbol.
NOTE:
The appliance must be connected
to an electrical circuit that is protected by
an external GFCI outlet.
HFM-72
VOLTAGE
PHASE CYCLE
/
HZ
AMPS
kW
208V
1
60
15.8
3.3
NEMA
6-20
P
20A, 250V
PLUG
230V
1
50/60
AVAILABLE UPON REQUEST
HFM-48
VOLTAGE
PHASE CYCLE
/
HZ
AMPS
kW
208V
1
50/60 10.5
2.2
NEMA
6-15
P
15A, 250V
PLUG
230V
1
50/60
AVAILABLE UPON REQUEST
E L E C T R I C A L
HFM-30
VOLTAGE
PHASE CYCLE
/
HZ
AMPS
kW
208V
1
50/60
5.2
1.1
NEMA
6-15
P
15A, 250V
PLUG
230V
1
50/60
AVAILABLE UPON REQUEST
#809 Operation & Care Manual •
5.
I N S T A L L A T I O N
ELECTRICAL CONNECTION