Grounding Instructions
This appliance must be grounded. In the event of

malfunction or breakdown, grounding will reduce the risk

of electric shock by providing a path of least resistance

for the electric current. This appliance is equipped with a

cord that has an equipment grounding conductor and a

grounding plug. The plug must be plugged into an

appropriate outlet that is properly installed and grounded

in accordance with all local codes and ordinances.

Important Points

Do not modify the plug provided with the appliance. If

the plug will not fit into the outlet have a properly

grounded outlet installed by a qualified electrician. Do

not cut, remove or bypass the grounding prong on the

washer power cord plug.

The washer power cord plug must be easily

accessible when the washer is operating.

When unplugging or plugging in the washer power

cord, grasp the plug. Do not pull on the power cord to

unplug the washer.

The household electrical supply must be suitable for

the voltage specification shown on the washer rating

plate (located inside the washer door, immediately

below the drum opening).
~ Purchase information; Page 4
See the table below for connection specfications and

fuse/breaker requirements.

The wiring for the electrical outlet circuit must be

sufficient to meet the appliance requirements. Use of a

Ground Fault Circuit Interrupter (GFCI) is

recommended.

Protect the power cord from physical damage, such as

being twisted, kinked, pinched, caught in a door, or

walked upon.

If the power cord is damaged, it must be replaced by a

qualified person to avoid a fire/shock hazard.

Replacement power cords are available through

Customer Service.
~ Customer service; Page 4

The washing machine must only be connected to an

individual branch circuit via a socket which has been

properly installed and grounded.

Make sure that:
- the power plug fits into the socket
- the wire size is sufficient
- the grounding system is properly installed:

The power cord may be replaced by an electrican

only. Replacement power cords are available from

Customer Service. To reduce the risk of fire or

electrical shock, DO NOT use an extension cord or an

adapter to connect the washing machine to the power

supply. If a ground fault circuit breaker is to be used,

only use the types marked with the following symbol:

z

. Only this symbol can guarantee compliance with

all current regulations.

Transporting the washer

Before transporting the washer

1.

Disconnect the washer power cord from the wall

outlet.

2.

Turn off the water supply to the washer.

3.

Disconnect water supply lines from the tap.

4.

Disconnect the drain hose from the drain location.

5.

Install the transport bolt assemblies as shown below.

Remove the transport bolt hole covers

1.

Remove all four transport bolt hole covers.

2.

Pull the tip of the arrow on the cover out slightly to

disengage the locking tab.

3.

Rotate the cover counterclockwise to remove. Repeat

for all 4 transport bolt hole covers.

Insert the transport bolt assemblies

1.

Each assembly consists of a plastic bushing and a

bolt that extends through the bushings. Unscrew the

bolt until the threaded end is flush with the end of the

plastic bushing.

2.

Insert the transportation bolt and bushing assembly as

shown. The metal housing slides around the bolt

through the slot in the plastic bushing as the bushing

is slid into place. The open part of the bushing slot

should be facing the direction shown to allow the

assembly to slide fully into place.

3.

When the bolt is in place screw it in until the bolt

threads engage the drum. Double check and ensure

bolts are screwed into threaded holes and not into

adjecent cracks or crevices. Repeat the process for all

4 transportation bolt assemblies before tightening any

all the way. Complete tightening all 4 bolt assemblies

until they are each snug in place.

Volts

Hertz

Ampers

Watts

208 - 240

60

12