Plumbing applications – Electrolux EP19WI30LS User Manual

Page 31

background image

29

Recirculation System

Combination Potable Water and Space Heating System

Cold Water Supply

Isolation
Kit(*4)

Gas Supply

Aquastat(*3)

Pump Control Signal(*2)

Relay for Pump
(if larger than 85 Watts)

Hot Water

Optional 8-10 Gallon
Storage Tank
(To alleviate cold water sandwich)

Globe
Valve

Pump(*1)

Expansion Tank
(Install according
to local code)

Fixtures

Hot Water Return

R

B

W

Pump

120VAC

105

Neutral
Ground

Live

S

Isolation
Kit(*1)

Gas Supply

Backflow Preventer
(optional)

Check
Valve(*3)

Cold Water
Supply

Optional
Expansion Tank(*6)

Mixing Valve(*5)

Hot Water

Pump(*2)

Flow Switch(*4)

Fixtures

Air Handler

Notes:
1. Size the pump to provide a maximum of 2 GPM
(7.5 L/min.) through the system at 10 ft (3m) of
head plus piping losses.
Adjust the flow using a globe valve and verify the
flow rate with the maintenance monitors.

2. Pump Control Signal is the preferred method
to control the recirculation pump.
For pumps larger than 85W, a relay connection
must be used. If the Pump Control Signal is not
used, an Aquastat may be used to control the
pump.
3. Use an Aquastat if the water heater is not controlling
the pump.
Set the Aquastat to 10°F (5°C) below the set
output temperature.
4. Electrolux recommends the use of an Isolation Kit
with the installation.
These kits include an integrated shut-off and service
valve with unions and a pressure relief valve.

Notes:

1. Electrolux recommends the use of an Isolation Kit with
the installation.
These kits include an integrated shut-off and service
valve with unions and a pressure relief valve.

2. Size the pump to provide a maximum of 3 GPM
(11.3 L/min.) with a head pressure equal to the loss
through the water heater and Air Handler.
3. Check valve required if it is not included with the pump.

4. Set the flow switch to deactivate the Air Handler when
the domestic hot water flow reaches 3 GPM (11.3 L/min.).
Adjust as necessary to prevent cycling.

5. If the system requires water for space heating at a higher
temperature than for other uses, means such as a
mixing valve shall be provided to temper the water for
the other uses to help prevent scalding.

7. The water heater cannot be used for space heating
applications only.

8. Only POTABLE water may be plumbed through
the water heater.

6. Expansion tank required if a backflow preventer is installed.

Use Honeywell Aquastat

(Model L6006A or L6006C)

Aquastat Wiring

Electrolux

Condensing

Tankless Gas
Water Heater

Electrolux

Condensing

Tankless Gas
Water Heater

12.

Plumbing Applications