Product information, Specifications – AMX Power Current Sensors PCS User Manual
Page 5
Product Information
1
PCS and PCS2 Power Current Sensors
Product Information
The Power Current Sensors (PCS) and Dual Power Current Sensors (PCS2) provide power current
status for AMX equipment. Examples of such equipment are video projectors, monitors, audio
receivers, and VCRs. The PCS and PCS2 detect the AC current drawn by the equipment plugged
into its AC receptacle. You can adjust either the PCS or PCS2 to detect full on, full off, and standby
power levels.
Specifications
The following tables list specifications for the PCS and PCS2.
PCS Specifications
Dimensions
3.13" x 2.23" x 2.5" (79.5 mm x 56.6 mm x 63.5 mm)
Weight
4 oz. (114 g)
Enclosure
Plastic black matte finish
Power Requirement
12 VDC @ 20 mA minimum
Connectors
4-pin captive screw connector
3-prong, grounded, 120 VAC receptacle
Indicators
• Standby LED
• On LED
Load Sensitivity
15 A 1800 W maximum (15 A @ 120 VAC maximum)
30 mA minimum
PCS2 Specifications
Dimensions
1.51" x 5.55" x 5.45" (38.4 mm x 141.10 mm x 138.4 mm)
Weight
1 lb. 10.8 oz. (816 g)
Enclosure
Metal black matte finish
Power Requirement
120 VAC @ 250 mA minimum
Connectors
6-pin captive screw connector
3-prong, grounded, 120 VAC receptacle
Dry Closure Relay Outputs
0.5 A @120 VAC or 1 A @ 28 VDC
Indicators
• 2 Standby LEDs
• 2 On LEDs
• Power LED
Load Sensitivity
10 A 1200 W maximum (combined fuses)
20 mA 2.4 W minimum 120 W maximum