Supply water piping

rDo not use PVC, iron, or any piping which has been

treated with chromates, boiler seal or other chemicals.

rMount a check valve and a shut off valve (near the inlet).
r*O PSEFS GPS UIF DMJFOU UP VTF UIF XBUFS IFBUFS

comfortably, 98.1 to 491 kPa (14 to 70 PSI) of
pressure is needed from the water supply.

Be sure to check the water pressure. If the

water pressure is low, the water heater cannot
perform to its full capability, and may become
a source of trouble for the client.

Drain piping

r&YQBOTJPO XBUFS NBZ ESPQ GSPN UIF QSFTTVSF

relief valve and wet the floor.

If necessary, provide drain piping or use a

drain hose to remove the water.

Hot water piping

r%POPUVTFMFBE 17$ JSPOPSBOZQJQJOHXIJDI

has been treated with chromates, boiler seal or
other chemicals.

r5IFMPOHFSUIFQJQJOH UIFHSFBUFSUIFIFBUMPTT

Try to make the piping as short as possible.

r6TF NJYJOH WBMWFT XJUI MPX XBUFS SFTJTUBODF

Use shower heads with low pressure loss.

r*G OFDFTTBSZ VTF B QVNQ PS PUIFS NFBOT UP

ensure that the supply water pressure to the
inlet of the heater does not fall below 29 PSI when
the maximum amount of water is being demanded.
Also install a pressure meter on the inlet. If this is
not done, local boiling will occur inside the water
heater causing abnormal sounds and decreasing
the durability of the heat exchanger.

Freeze Prevention

r'SFF[JOHJTQSFWFOUFEXJUIJOUIFEFWJDFBVUPNBUJDBMMZVOMFTTUIFPVUTJEFUFNQFSBUVSFXJUIPVUXJOE

is below -30°F (-35°C).

* When combustion air is supplied from the indoors, the room temperature must be greater than 32°F (0°C)
to prevent freezing and the room inside must not have negative pressure.
r*GUIJTNPEFMJTJOTUBMMFEJOBOBSFBXIFSFUIFPVUTJEFUFNQFSBUVSFDBOBQQSPBDIGSFF[JOHDPOEJUJPOT

of -30°F (-35°C) or below, then additional freeze protection measures must be used. For temporary
freeze protection measures, refer to the Use and Care Manual.

r5IFGSFF[FQSFWFOUJPOIFBUFSTXJMMOPUQSFWFOUUIFQMVNCJOHFYUFSOBMUPUIFVOJUGSPNGSFF[JOH

Protect this plumbing with insulation, heat tape or electric heaters, solenoids, or pipe covers.

r*OPSEFSGPSUIFGSFF[FQSFWFOUJPOIFBUFSTUPPQFSBUF UIFXBUFSIFBUFSNVTUIBWFQPXFSBUBMMUJNFT