Internal controller, External device output terminal (out), Internal connection chart – Canon VB-C300 User Manual
Page 51
3-5
Appendix
Loads connected to the output terminals should be within the following ratings:
Rating across the output terminals: Up to 50 VDC
Continuous load current: 100 mA or less
I/O Terminals
Internal controller
Input terminal IN1, IN2
+
-
Output terminal OUT1
10k
Ω
10k
Ω
10k
Ω
+3.3V
0.1
μ F
External Device Output Terminal (OUT)
The external device output terminal consists of a pair of two output terminals (OUT). There is no
distinction between “ + ” and “ - ” for OUT. The NC Viewer switches the 2 output terminals to
disconnected or connected condition. The output terminals use photo couplers and are separate
from the internal circuit in the VB-C300.
Tip
The wire appropriate for external device cable is as follows.
AWG: # 28 - # 22
Conductor diameter:
ø
0.32 - 0.65 mm (0.013 - 0.026 in)
Internal Connection Chart
External
device
External
device