beautypg.com

Internal controller, External device output terminal (out), Internal connection chart – Canon VB-C300 User Manual

Page 51

background image

3-5

Appendix

Loads connected to the output terminals should be within the following ratings:

Rating across the output terminals: Up to 50 VDC

Continuous load current: 100 mA or less

I/O Terminals

Internal controller

Input terminal IN1, IN2

+

-

Output terminal OUT1

10k

Ω

10k

Ω

10k

Ω

+3.3V

0.1

μ F

External Device Output Terminal (OUT)

The external device output terminal consists of a pair of two output terminals (OUT). There is no

distinction between “ + ” and “ - ” for OUT. The NC Viewer switches the 2 output terminals to

disconnected or connected condition. The output terminals use photo couplers and are separate

from the internal circuit in the VB-C300.

Tip

The wire appropriate for external device cable is as follows.

AWG: # 28 - # 22

Conductor diameter:

ø

0.32 - 0.65 mm (0.013 - 0.026 in)

Internal Connection Chart

External
device

External
device