beautypg.com

Nilfisk-ALTO SR 1301 B User Manual

Page 91

background image

USER MANUAL

ENGLISH

SR 1301 B

1463436000(1)2008-05 A

29

FUSE CHECK/REPLACEMENT/RESET

Drive the machine on a level fl oor and engage the parking brake with the pedal (75) and the lever (68).

1.

Turn the ignition key (67) to “0”.

2.

Open the hood (22) and fasten it with the support rod (36).

3.

Disconnect the battery connector (25).

4.

Lamellar fuse check/replacement

Remove the cover (A, Fig. 28) and mark the positions of the fuses shown on the adhesive.

5.

Check/replace the relevant fuse among the following (B):

6.

F1 fuse (30 A): Key circuit

F2 fuse (30 A): Filter shaker

F3 fuse (30 A): Vacuum system

F4 fuse (30 A): Hydraulic pump

F5 fuse (10 A): Flashing light (optional)

F6 fuse (10 A): Working light (optional)

F7 fuse (10 A): Hopper actuator

F8 fuse (30 A): Spare fuse

Main fuse check/replacement

Remove the screws (C, Fig. 28), then remove the cover (D).

7.

Remove the nuts (E).

8.

Check replace the main fuse F0 (150 A) (F)

9.

Circuit breaker check

Check for deactivation of one of the following fuses, then reset it after the relevant motor has cooled down:

10.

FA fuse (H, Fig. 28): Right side broom motor circuit breaker

FB fuse (I): Left side broom motor circuit breaker (optional)

FC fuse (G): Main broom motor circuit breaker

Assembly

Assemble the components in the reverse order of disassembly.

11.

S311447

Figure 28