beautypg.com

Technical specifications, Gas data natural gas 2h (g20), Gas data butane 3+ (g30) – A.O. Smith BTI - 65 User Manual

Page 2: Gas data propane 3+ (g31), Draw-off capacity, Electrical data, General, Shipping data

background image

BTI

Technical specifications

Gas data natural gas 2H (G20)

Input*

kW

18.1

23.1

27.4

Output

kW

12.7

16.2

19.2

Inlet pressure

mbar

20

20

20

Burner pressure

mbar

12

11,5

10

Gas consumption**

m

3

/h

1.7

2,2

2.6

Diameter pilot orifice

mm

0.56/0.41

0.56/0.41

0.56/0.41

Diameter main orifice

mm

3.4

3,9

4.5

Max. flue gas temperature

°C

265

275

275

Flue gas discharge

kg/h

27

55.2

53.2

Gas data butane 3+ (G30)

Input*

kW

17.2

21.8

29.6

Output

kW

12.3

15.7

21.2

Inlet pressure

mbar

30

30

30

Burner pressure

mbar

-

-

-

Gas consumption**

kg/h

1.3

1.6

2.2

Diameter pilot orifice

mm

0.23

0.23

0.23

Diameter main orifice

mm

1.9

2.2

2.5

Max. flue gas temperature

°C

265

275

275

Flue gas discharge

kg/h

-

81.1

74.8

Gas data propane 3+ (G31)

Input*

kW

16.4

20.9

28.6

Output

kW

11.7

15

20.4

Inlet pressure

mbar

37

37

37

Burner pressure

mbar

-

-

-

Gas consumption**

kg/h

1.2

1,5

2,0

Diameter pilot orifice

mm

0.23

0.23

0.23

Diameter main orifice

mm

1.9

2.2

2.5

Max. flue gas temperature

°C

265

275

275

Draw-off capacity

Storage capacity

l

178

265

355

Max. temperature setting

°C

80

80

80

30 min. ∆T=44°C

l

281

396

508

60 min. ∆T=44°C

l

405

554

713

90 min. ∆T=44°C

l

529

713

871

120 min. ∆T=44°C

l

652

871

1070

Continuous ∆T=44°C

l/h

247

375

399

Heating-up time ∆T=44°C

min.

43

42

53

30 min. ∆T=50°C

l

248

348

447

60 min. ∆T=50°C

l

356

488

612

90 min. ∆T=50°C

l

465

627

777

120 min. ∆T=50°C

l

574

767

992

Continuous ∆T=50°C

l/h

218

330

351

Heating-up time ∆T=50°C

min.

49

48

61

30 min. ∆T=55°C

l

225

317

406

60 min. ∆T=55°C

l

324

443

556

90 min. ∆T=55°C

l

423

570

706

120 min. ∆T=55°C

l

522

697

856

Continuous ∆T=55°C

l/h

198

300

319

Heating-up time ∆T=55°C

min.

54

53

67

Electrical data

Power consumption

W

30

Power supply

VAC/Hz

230(-15/+10%) / 50

General

Anodes

-

1

Maximum working pressure

bar

8

Maximum weight

kg

266

382

499

Shipping data

Weight empty

kg

93

122

149

Weight incl. packaging BTT / BTI

kg

105

140

167

Width packaging

mm

670

780

780

Height packaging

mm

1690

1640

1830

Depth packaging

mm

730

870

870

BTI 65

BTI 85

BTI 100

*

Gas data on gross value

**

Gas consumption at 15°C and 1013.25 mbar

This manual is related to the following products: