beautypg.com

On off – Agri-Fab 45-02113 User Manual

Page 7

background image

7

21. Position the flow control mounting bracket (figure 12).

a. Push on flow control arm until it locks in "OFF"

position.

b. Slide flow control mounting bracket along tube

until closure plate in bottom of hopper just closes.

c. Snug the 1/4" lock nuts just enough to hold flow

control mounting bracket in place.

d. Set adjustable stop at "5". Pull flow control arm

against stop. Verify that closure plate has opened
about half way.

e. If closure plate does not open half way, it may be

closed too far at "OFF". Adjust position of flow
control mounting bracket until closure plate will
open about half way at "5" and still close when arm
is locked in "OFF".

Tighten

1/4" lock nuts.

FIGURE 12

OFF

ON

1

2

3

4

6

7

8

9

10

5

FLOW

CONTROL

ARM

ON

OFF

AJDUSTABLE

STOP

SETTING "5"