Timeguard TRT036 User Manual
Page 4
1. Introduction
TRT products are a cost effective comprehensive
range of thermostats and controllers designed
for internal use only.
The TRT036 is a two channel programmer
dedicated to central heating and hot water,
with automatic summer/winter time
changeover (which can be cancelled), 5 day
plus 2 or 7 (individual) day programming,
pumped or gravity fed system, holiday mode,
boost function, advance to next programme
and permanent on/off over ride. There are
three timed control periods per day.
The unit is fitted with a factory installed
battery which gives up to 24 hours back up
of time, date and programmes in the event
of a mains failure.
It is designed to be surface mounted on its
supplied wall plate.
The electrical supply must be isolated before
removing the thermostat from the wall plate.
2. Siting
The TRT036 should be located at a position
which eases wiring runs and gives good access
for programming. It should be mounted
approximately 1.5m above floor level.
3. Installation
This product should be installed by a qualified
installer to current installation standards.
If in any doubt contact the Timeguard Helpline
020 8450 0515.
Always isolate the mains supply before
removing the unit from its wall plate.
The TRT036 is designed to be surface mounted
on the supplied wall plate.
Isolate 230VAC mains supply.
Incoming and outgoing cable should be 1.5mm sq.
Contents
TRT036 programmer
TRT036 wall plate
TRT036 instruction leaflet
2 x wall plugs
2 x screws
Programmers allow you to set ‘On’ and ‘Off’
time periods. Some models switch the central
heating and domestic hot water on and off at
the same time, while others allow the domestic
hot water and heating to come on and go off
at different times.
Set the ‘On’ and ‘Off’ time periods to suit your
own lifestyle. On some programmers you must
also set whether you want the heating and
hot water to run continuously, run under the
chosen ‘On’ and ‘Off’ heating periods, or
be permanently off.
The time on the programmer must be correct.
Some types have to be adjusted in spring and
autumn at the changes between Greenwich
Mean Time and British Summer Time.
You may be able to temporarily adjust the
heating programme, for example, ‘Override’,
‘Advance’ or ‘Boost’. These are explained in
the manufacturer’s instructions.
The heating will not work if the room thermostat
has switched the heating off. And, if you have a
hot-water cylinder, the water heating will not
work if the cylinder thermostat detects that the
hot water has reached the correct temperature.
®
What is a programmer?
...an explanation for householders
Advance Mode
Advance Mode
select
set
reset
Fig. 1a
TRT036 7 Day Digital Programmer
Selects time,
temperature or
date to be changed
Reset
button
Advance/mode
button
Up and down
buttons
(used in
programming)
Initiates programme
setting sequence and in
conjunction with the select
button initiates time and
date setting sequence
Border illuminates
when +/- buttons
are pressed
and for 15 seconds
after release
7 5 -
2
PROGRA
M
SYSTEM
P
G
Wall plate retaining screws
(at bottom of TRT036)
Gravity or Pumped jumper
(shown in P-pumped position)
7 day or 5 + 2
jumper (shown in 7
(individual) day position)
Fig. 2
Rear View of TRT036
Fig. 3
Back Plate Removed
NC1
NC2
NO1
NO2 N
L
Alternative
fixing holes
Mount the wall plate in this configuration only
Product
retaining
screws
Terminal for
retaining
continuity
of earth
Fig. 4
Remove wall plate from unit, by undoing
retaining screws, and pivoting the bottom of the
unit outwards. The unit can then be lifted off.
Pass incoming wires through opening in wall plate,
and fix wall plate securely to the wall, using screws
provided. The screws which secure the product to
the wall plate should point downwards.
Allow sufficient excess cable to wire up the unit,
but not too much to make it difficult to close
the unit to the wall plate.
Connect the conductors to the relevant
terminal, according to the wiring diagram
on the wall plate (or below). Ensure that
the curved brass washer grips the conductor.
Wiring Diagram
CH
CH HW HW
N
N
L
L
230 VAC
ON
ON OFF
OFF
NC1
NC2
NO1
NO2
Advance Mode
Advance Mode
select
set
reset
Fig. 1
TRT036 7 Day Digital Programmer
Day of
week
Time of day/
programme
time which
flashes during
setting
Blue
illuminated
light/holiday
button
Shows when
heat is
demanded
Central
heating
channel
status
Hot
water
channel
status
Blue
illuminated
boost
button
Stylish
design
Pull down
flap for
programming
Blue electro-
luminescent
screen
Note:
Check boiler
instructions
before
connecting.