7 day digital programmer, Operating & installation instructions, 3 year guarantee – Timeguard TRT034 User Manual
Page 5: Cat. no. trt034, Specifications, Operation, Helpline
7 Day Digital
Programmer
Cat. No. TRT034
Operating & Installation Instructions
These apply to every day independent of whether
weekday/weekend (5-2) or individual (7) day
option is chosen.
Note: to omit days and programmes please refer
to “Omitting days and programmes”
To change from default values, proceed as follows:
Press set and MON will flash (with programme (P)
1 on time displayed). Press select and P1 on hour
digit(s) will flash, use
buttons to get the
required hours.
Press select and P1 on minute digits will flash,
use
buttons to get the required minutes.
Press select and P1 off hour digits will flash,
use
buttons to get the required hours.
Press select and P1 off minute digits will flash,
use
buttons to get the required minutes.
Press select and programme (P) 2 on hour digit(s)
will flash, use
buttons to get the required
hours.
Press select and programme (P) 2 on minute digit(s)
will flash, use
buttons to get the required
minutes. This procedure of alternatively using
select and
can be continued to set
programmes P2 and P3.
Once complete the second day can be started by
pressing the set button when MON will begin to
In 5-2 day mode the weekend can be omitted by
using the same technique for the 2 day (Sat &
Sun) programmes.
A programme (usually P2) can also be omitted
for a given day by making the P2 on and off times
the same. This can also be applied to P1 and P3
if required.
Boost
In operating mode, there is a boost facility
for between 1 and 9 hours in one hour steps.
Press the boost button the required number of
times for the number of hours of boost required.
The programmer returns to operating mode
15 seconds after the last button push. To cancel
boost, press the boost button until 0 hours is shown.
Press and hold the light button and the
programmer will enter holiday mode. Use the
buttons to set the required number of days.
The programmer will return to operating mode
15 seconds after the last button push. To exit holiday
mode, press and hold the light button again.
Screen illumination
Press the light button briefly at anytime,
and the screen will illuminate for 15 seconds.
To clean use a clean dry cloth only. Do not use
any liquid cleaners.
5. Specifications
Current rating: 3 (1) A
Voltage:
230V, 50Hz
Switch type:
Single pole, double throw
(SPDT)
Operating
temperature
range:
0ºC to 50ºC
Complies with: BS EN 60730
Conforms to
directives:
Conforms to latest directives
Micro
disconnection: Type 1.B control action
Setting time and date
To programme the current time and date,
simultaneously press and hold both the select
and set buttons for 3 seconds.
The option 12 hour or 24 hour is displayed and
needs
to be set. Use the up and down
buttons
to select the required mode.
Press select to move to setting the hours.
Use the up and down buttons
to set
the hour, and press select to set the minutes.
Again use the up and down buttons
to set
the minutes, and then select to set the year (y),
the month (m), the day (d), and automatic
summer/winter time change or daylight saving
(dls) on/off, in each case using the up and down
buttons
. Once the time and date have been
set, press set to exit back to the operating mode.
If at any time a button is not pressed for
15 seconds, the unit will return to operating mode.
Individual (7 day) programming on/off times
The default on/off times are as follows:
6:00 AM
on
8:00 AM
off
10:00 PM
on
12:00 PM
off
6:00 PM
on
10:00 PM
off
flash. Press the
butons to get the required
day for programming, then press select and this
day can be programmed as Monday above.
Complete all 7 days in the same manner. If set is
then pressed twice the TRT034 will return to
operating mode.
This defaults to permanently off – refer to “Setting
the operating mode” to get into timed mode.
Weekday/weekend (5-2) programming
on/off times
For 5-2 day mode, time periods will need to be
programmed for M-F (Mon-Fri) and then for S-S
(sat-sun). Only 2 sets of times need to be
programmed, not 7.
Setting the operating mode
Once programmed, the default mode is
‘continuously off’. To enter programmed mode,
press the advance/mode button. One press changes
the output to ‘continuously on’, two presses changes
to ‘programmed’, and three presses changes to
‘advance to next programme’. In advance mode,
once the next time period has past, the programmer
returns to programmed mode.
Omitting days and programmes
Days can be omitted by entering the same time in
each of the 3 on/off programmes for that day.
4. Operation
Decide whether weekday/weekend (5-2) or
individual (7) day programming is required, and move
the jumper on the rear of the product (see Fig. 2).
It is important to make this decision first, as after
any change of jumper position, reset needs to be
pressed, which will return the unit to default time
and programme.
Reset
When programming a new unit or one that has
been disconnected from the mains for more than
24 hours, open the program access flap and press
the reset button (see Fig. 1a) using a pen or
similar implement which will clear the memory.
All of the screen segments will show briefly, and
then the default programme will be displayed.
This unit is double insulated, and hence does
not need connection to earth. If earth continuity
is required, please use earth terminal on wall plate.
To reinstall the unit on the wall plate hook the top
of the unit over the retaining tabs, and push firmly
back. There will be some resistance from the terminals.
Once in place, secure with the retaining screws.
Restore mains to the unit after checking all system
wiring is complete.
For a product brochure please contact:
Timeguard Ltd. Victory Park, 400 Edgware Road,
London NW2 6ND Tel: 020 8452 1112
or email [email protected]
A Group company
67-058-325 (issue 2)
HELPLINE
020 8450 0515
or email [email protected]
For assistance with the product please contact:-
3 Year Guarantee
In the unlikely event of this product becoming
faulty due to defective material or manufacture
within 3 years of the date of purchase, please
return it to your supplier in the first year with proof
of purchase and it will be replaced free of charge.
For years 2 and 3 or any difficulty in the first year
telephone the helpline on
020 8450 0515.
Note: a proof of purchase is required
in all cases. For all eligible replacements (where agreed by
Timeguard Ltd) the customer is responsible for all shipping/
postage charges for sending replacements outside the UK.
All shipping costs are to be paid in advance before
a replacement is sent.