7 Day Digital

Programmer

Cat. No. TRT034

Operating & Installation Instructions

These apply to every day independent of whether

weekday/weekend (5-2) or individual (7) day
option is chosen.
Note: to omit days and programmes please refer

to “Omitting days and programmes”

To change from default values, proceed as follows:

Press set and MON will flash (with programme (P)

1 on time displayed). Press select and P1 on hour

digit(s) will flash, use

buttons to get the

required hours.
Press select and P1 on minute digits will flash,

use

buttons to get the required minutes.

Press select and P1 off hour digits will flash,

use

buttons to get the required hours.

Press select and P1 off minute digits will flash,

use

buttons to get the required minutes.

Press select and programme (P) 2 on hour digit(s)

will flash, use

buttons to get the required

hours.
Press select and programme (P) 2 on minute digit(s)
will flash, use

buttons to get the required

minutes. This procedure of alternatively using

select and

can be continued to set

programmes P2 and P3.

Once complete the second day can be started by

pressing the set button when MON will begin to

In 5-2 day mode the weekend can be omitted by

using the same technique for the 2 day (Sat &
Sun) programmes.

A programme (usually P2) can also be omitted

for a given day by making the P2 on and off times
the same. This can also be applied to P1 and P3

if required.
Boost
In operating mode, there is a boost facility

for between 1 and 9 hours in one hour steps.

Press the boost button the required number of

times for the number of hours of boost required.

The programmer returns to operating mode

15 seconds after the last button push. To cancel

boost, press the boost button until 0 hours is shown.
Press and hold the light button and the

programmer will enter holiday mode. Use the

buttons to set the required number of days.

The programmer will return to operating mode

15 seconds after the last button push. To exit holiday

mode, press and hold the light button again.
Screen illumination
Press the light button briefly at anytime,
and the screen will illuminate for 15 seconds.

To clean use a clean dry cloth only. Do not use

any liquid cleaners.

5. Specifications

Current rating: 3 (1) A

Voltage:

230V, 50Hz

Switch type:

Single pole, double throw

(SPDT)

Operating
temperature

range:

0ºC to 50ºC

Complies with: BS EN 60730

Conforms to

directives:

Conforms to latest directives

Micro
disconnection: Type 1.B control action

Setting time and date

To programme the current time and date,

simultaneously press and hold both the select

and set buttons for 3 seconds.

The option 12 hour or 24 hour is displayed and

needs

to be set. Use the up and down

buttons

to select the required mode.

Press select to move to setting the hours.
Use the up and down buttons

to set

the hour, and press select to set the minutes.

Again use the up and down buttons

to set

the minutes, and then select to set the year (y),
the month (m), the day (d), and automatic

summer/winter time change or daylight saving

(dls) on/off, in each case using the up and down

buttons

. Once the time and date have been

set, press set to exit back to the operating mode.
If at any time a button is not pressed for

15 seconds, the unit will return to operating mode.

Individual (7 day) programming on/off times

The default on/off times are as follows:

6:00 AM

on

8:00 AM

off

10:00 PM

on

12:00 PM

off

6:00 PM

on

10:00 PM

off

flash. Press the

butons to get the required

day for programming, then press select and this
day can be programmed as Monday above.

Complete all 7 days in the same manner. If set is
then pressed twice the TRT034 will return to

operating mode.

This defaults to permanently off – refer to “Setting

the operating mode” to get into timed mode.
Weekday/weekend (5-2) programming

on/off times
For 5-2 day mode, time periods will need to be
programmed for M-F (Mon-Fri) and then for S-S

(sat-sun). Only 2 sets of times need to be

programmed, not 7.
Setting the operating mode

Once programmed, the default mode is

‘continuously off’. To enter programmed mode,

press the advance/mode button. One press changes

the output to ‘continuously on’, two presses changes

to ‘programmed’, and three presses changes to

‘advance to next programme’. In advance mode,

once the next time period has past, the programmer

returns to programmed mode.
Omitting days and programmes
Days can be omitted by entering the same time in
each of the 3 on/off programmes for that day.

4. Operation

Decide whether weekday/weekend (5-2) or

individual (7) day programming is required, and move

the jumper on the rear of the product (see Fig. 2).
It is important to make this decision first, as after
any change of jumper position, reset needs to be

pressed, which will return the unit to default time
and programme.
Reset
When programming a new unit or one that has
been disconnected from the mains for more than
24 hours, open the program access flap and press

the reset button (see Fig. 1a) using a pen or
similar implement which will clear the memory.
All of the screen segments will show briefly, and

then the default programme will be displayed.

This unit is double insulated, and hence does

not need connection to earth. If earth continuity
is required, please use earth terminal on wall plate.
To reinstall the unit on the wall plate hook the top
of the unit over the retaining tabs, and push firmly
back. There will be some resistance from the terminals.

Once in place, secure with the retaining screws.
Restore mains to the unit after checking all system

wiring is complete.

For a product brochure please contact:

Timeguard Ltd. Victory Park, 400 Edgware Road,

London NW2 6ND Tel: 020 8452 1112

or email [email protected]

A Group company

67-058-325 (issue 2)

HELPLINE

020 8450 0515

or email [email protected]

For assistance with the product please contact:-

3 Year Guarantee

In the unlikely event of this product becoming

faulty due to defective material or manufacture

within 3 years of the date of purchase, please

return it to your supplier in the first year with proof

of purchase and it will be replaced free of charge.

For years 2 and 3 or any difficulty in the first year

telephone the helpline on

020 8450 0515.

Note: a proof of purchase is required

in all cases. For all eligible replacements (where agreed by

Timeguard Ltd) the customer is responsible for all shipping/

postage charges for sending replacements outside the UK.

All shipping costs are to be paid in advance before

a replacement is sent.