beautypg.com

Electronic room thermostat, Operating & installation instructions, 3 year guarantee – Timeguard TRT030 User Manual

Page 7: Cat. no. trt030, Helpline, Operation, Wiring diagram, Back plate removed, Specifications

background image

For a product brochure please contact:

Timeguard Ltd. Victory Park, 400 Edgware Road,

London NW2 6ND Tel: 020 8452 1112

or email [email protected]

A Group company

67-058-322 (issue 3)

HELPLINE

020 8450 0515

or email [email protected]

For assistance with the product please contact:-

3 Year Guarantee

In the unlikely event of this product becoming

faulty due to defective material or manufacture

within 3 years of the date of purchase, please

return it to your supplier in the first year with proof

of purchase and it will be replaced free of charge.

For years 2 and 3 or any difficulty in the first year

telephone the helpline on

020 8450 0515.

Note: a proof of purchase is required

in all cases. For all eligible replacements (where agreed by

Timeguard Ltd) the customer is responsible for all shipping/

postage charges for sending replacements outside the UK.

All shipping costs are to be paid in advance before

a replacement is sent.

4. Operation

Use adjuster dial to set desired temperature.

Blue LED is lit when temperature is below

desired value, indicating that the thermostat is
calling for heat from the boiler. Once the room

reaches the desired temperature the LED turns

off and the TRT030 ceases to call for heat from
the boiler.

The temperature swing can be adjusted between
1°C and 0.5°C by selecting a jumper found on
the rear of the unit (see Fig. 2).

We suggest using the 0.5ºC position unless the
boiler turns on and off too rapidly.

PID can also be selected on or off using a
jumper on the rear of the unit (see Fig. 2).

To reinstall the unit on the wall plate first
ensure the wall plate retaining screws are
loosened enough to clear the TRT030 body
then engage the top of the TRT030 onto the

wall plate retaining tabs (see Fig. 4), and push
firmly downwards and then upwards. There will

be some resistance from the terminals. Once in
place, secure with the retaining screws.

Restore mains to the unit after checking all
system wiring is complete.

Remove wall plate from unit, by undoing
retaining screws (see Fig. 2), and pivoting the

bottom of the unit outwards. The TRT030 can
then be lifted off.
Pass the incoming wires through the opening in

wall plate, and fix wall plate securely to the wall,
using the screws provided (and wall plugs if
necessary) provided. The screws which secure

the product to the wall plate should be at the
bottom (see Fig. 2).

Allow sufficient excess cable to wire up the unit,
but not too much to make it difficult to close

the unit to the wall plate.

Connect the conductors to the relevant terminals,
according to the wiring diagram on the wall

plate (or Fig. 3 below). Ensure that the curved
brass washer grips the conductor.

N

NO

N

L

L

Fig. 3

Wiring
Diagram

Electronic Room

Thermostat

Cat. No. TRT030

Operating & Installation Instructions

NO

N

L

Fig. 4

Back Plate Removed

Alternative

fixing holes

Retaining

tabs

Mount the wall plate in this

configuration only

Product retaining

screws

Terminal for maintaining

continuity of earth

Note:

Check boiler

instructions

before

connecting.

This unit is double insulated, and hence does not
need connection to earth. If earth continuity is
required, please use earth terminal on wall plate.

5. Specifications

Current rating:

6 (2) A

Voltage:

220-240V, 50HZ

Switch type:

Single pole, single throw

(SPST)

Operating
temperature range: 0°C to 50°C

Set temperature
range:

5°C to 30°C

Complies with:

BS EN 60730

Conforms to

directives:

Conforms to latest directives

Temperature

swing:

1°C or 0.5°C

Micro

disconnection:

Type 1.B control action

This can help in reducing temperature over-shoot.
We suggest using the PID on position.

To clean use a clean dry cloth only. Do not use
any liquid cleaners.