Sterlco BP 1000 Series Beside the Press Granulators User Manual
Page 17
1000 Series Granulators
Chapter 2: Functional Description
17 of 45
Figure 2: Noise Test Specifications
Model
Motor
Power
Impeller Speed Production
∗
75% Production Test Supply (SPI
Method)
kW
Rev./min.
Kg/h
Kg/h
Pcs. No./min.
Kg/h
1012
5.5
340
140
105
24
99.5
1018
7.5
340
200
150
36
149.0
Figure 3: Average Sound Levels
Model 1012 Sound Enclosed
Model 1018 Sound Enclosed
Position
Sound Levels in dB(A)
Position
Sound Levels in dB(A)
1
84.3
1
86.0
2
83.6
2
85.6
3
82.6
3
84.1
4
82.2
4
84.1
Lpm
93.2
Lpm
85.0
Figure 4: Noise Test Method
∗ All Granulators provided with 5/16” (8 mm) Diameter Hole Screen.
Machine being tested
Feeding Point
Operator
Position
1
2
3
4
1.0 m
1.0 m
Position of the
photometric
detectors (h=1.5 m)
S.P.I Material Sample
Type: PVC 1120 SCH40
ASTMD-1785
Length: 145 mm
Outer Dia.: 33.5 mm
Inner Dia.: 26.5 mm
Thickness: 3.5 mm
Mass: 0.069 kg