Sterlco BP800 Series Granulators User Manual
Page 35

800 Series beside-the-press
Chapter 6: Troubleshooting
35 of 43
Electrical Problems
Problem
Possible Cause
Possible Remedy
Machine stops for no
apparent reason
Safety switch has stopped
power
Check that the knobs that
operate the safety switch are
tightened
Electric motor does not start
No power
Check fuses
Overload failure
Check amperage of electric
motor
Safety switch not working
Check and replace
Cutting chamber too full
Empty cutting chamber
Motor starts but does not
speed up or take a load
Excessive drive belt tension
Check belt tension and adjust
Motor connected to power
source incorrectly
Reconnect correctly
Defective starter winding
Check current in each phase.
If substantial difference
between phases, contact
motor manufacturer
Motor starts, but does not
gain speed
Bearing excessively worn
Replace bearings
Cutting chamber full
Empty cutting chamber