beautypg.com

Sterlco SEU Series Economical Water TCU User Manual

Page 16

background image

WTR1-600

Chapter 2: Functional Description

16 of 42

Figure 1

Typical Control Unit and Specifications

Direct Injection















Model

Dimensions

Shipping

number

Pump

H

W

D

weight

460 / 230

hp

kW

gpm

lpm

psig

kPa

in.

cm in. cm in. cm lbs.

Kg

ECU/SEU

9 kW heater

¾

0.56

30

113.6

25

172.4

25¾” 65.4 12 “ 30.5 23” 58.4

210

96

1

0.75

35

132.5

30

206.9

2

1.50

50

189.3

30

206.9

3

2.24

60

227.1

35

241.3

5

3.73

75

283.9

54

372.3

240 109

5.60

90

454.2

63

434.4

Figure 2: Economical Series Unit Full-Load Amps

Model

Full-load amps at 460 volts

hp

kW

9 kW heater 12 kW heater

0.75 hp 0.56 kW

12.7 amps

16.5 amps

1.00 hp 0.75 kW

13.1 amps

16.9 amps

2.00 hp 1.50 kW

14.7 amps

18.5 amps

3.00 hp 2.24 kW

16.1 amps

19.9 amps

5.00 hp 3.73 kW

18.9 amps

22.7 amps

7.50 hp 5.60 kW

22.3 amps

26.1 amps