Sterlco SDA Series Medium Capacity Dehumidifying Dryer User Manual
Page 47

Cabinet Series Dehumidifying Dryer
47
Level 2 Cn5L input shift lower limit
-999.9 to 999.9
°C
0.0 Default
Mode Parameter
Setting
range
Default
Factory
setting
Setup
Cn-t Input Type
0 to 21
2
17
Setup
Cn-H Scaling Upper Limit
Scaling Lower Limit +1 to
9999 EU
-100
15
°F/-9C
Setup
Cn-L Scaling Lower Limit
-1999 to SP Setting Upper
Limit –0.1 EU
0
-40
°F/-40C
Setup
dP Decimal Point
0 to 3
0
Default
Setup
CnCE Parameter Initialize
Yes/No
No
Default
Setup
6Ut1 Control Output 1
Assignment
Heat/Cool/Alarm 1/Alarm 2/
Alarm 3/LBA
Heat COOL
Setup
6Ut2 Control Output 2
Assignment
Heat/Cool/Alarm 1/Alarm 2/
Alarm 3/LBA
AL-1 Default
SetUp
Sub 1 Auxiliary Output 1
Assignment
Alarm 1/Alm 2/Alm 3/LBA/S.
ERR/E333
AL-2 Default
Setup
ALt1 Alarm 1 Type
0 to 11
2
8
Setup
AL1n Alarm 1 open in alarm
NO/NC
NO
Default
Setup
ALt2 Alarm 2 Type
0 to 11
2
8
Setup
AL2n Alarm 2 open in alarm
NO/NC
NO
Default
Setup
6rEU Direct/Reverse
Operation
OR-R/OR-D OR-R
Default
Expansion SL-H Set Point Upper Limit
SP Lower Limit +1 to
Scaling Upper Limit
1300
15
°F/-9C
Expansion SL-L Set Point Lower Limit
Scaling Upper Limit to Sp
Lower Limit
-200
-40
°F/-40C
Expansion CntL PID/ON/OFF
PID/ON-OFF
PID
ON-OFF
Expansion
rESt Standby Sequence
Reset Setting Method
0/1 0
Default
Expansion
rEt Automatic Return of
Display Mode
0 to 99 SEC
0
Default
6-8 Restoring the E5CK Temperature Controller and Dew Point
Meter to Factory Setup
If preset parameters on the controller have been tampered with and it no longer properly controls
temperature and displays dew point, you can restore the controller to factory setup.