beautypg.com

Tamper alert, Silent arming/disarming, Passive arming – ScyTek Electronics Galaxy 5000RS-DBP User Manual

Page 24

background image

Page 20 - Galaxy 5000RS-DBP

Tamper Alert

If the system was triggered while away, the LED will flash to indicate which zone triggered the system after

disarming and turning the ignition ON. The LED indication will repeat 8 times.

LED Flashes (60 seconds):

1 flash

=

optional sensor

2 flashes

=

shock sensor

3 flashes

=

network based sensor

4 flashes

=

door

6 flashes

=

hood/trunk

example: flash-flash-pause-flash-flash-pause = shock sensor

Silent Arming/Disarming

The Galaxy 5000RS-DBP Series system can be programmed to operate the system without Arm/Lock and

Disarm/Unlock chirp/honk confirmations. When programmed for full-time silent operation, the siren will

sound only when the system is triggered.
The system is also capable of temporary silent operation if desired. Pressing the Shift button before

Arming/Locking or Disarming/Unlocking, the system will bypass the chirp/honk confirmations and allow

one-time silent operation.

Note: The open zone warning chirps will not be bypassed when the system is Armed or Disarmed silently.*

Passive Arming

When programmed for the optional Passive Arming feature, the system arms itself automatically, each time

the ignition is turned off and all of the doors, hood, and trunk are closed.
To start the Passive Arming Process:

1. Turn off the ignition.**
2. Open the door and exit the vehicle.

· Once all doors are closed and the dome light is off, the LED will begin flashing rapidly.

· The parking lights will flash twice indicating the Passive Arming sequence has begun.

3. After 30 seconds,

· The siren will chirp.

· The parking lights will flash.

· The doors will lock.***

· The status LED will begin flashing.

4. The system is now armed.

** The ignition must have been on for

at least 5 seconds

** * If the Passive Locking feature is selected.

This manual is related to the following products: