Apw ezfill hot food wells – APW Wyott SHFWEZ-12D User Manual
Page 5
5
APW EZFILL HOT FOOD WELLS
Part Numbers Beginning with WHFW
INSTALLATION
OPTIONS
OPERATION
CLEANING
MODEL
OUTSIDE DIMENSIONS
CUT-OUT
CONTROL CUT-OUT
SHIP WT.
SM50EZ-12D
WELL
15.21
12.71
13.49
13.75
11.50
5.0
12.5
22 Lbs.
(38.6)
(32.3)
(34.3)
(34.9)
(29.2)
(12.7)
(31.8)
(10.6 Kg)
A
B
C
E
D
F
G
GENERAL SPECIFICATIONS (APW EZFILL HOT FOOD WELLS)
Description: Lever Operated Drain Valve
Stock Number: 56360
Drain Manifold: Fabricated to Unit, Required
MODEL
ELECTRICAL RATINGS 500 EA. @ 208V / 660 EA. @ 240V
VOLTS
WATTS
AMPS (1 Phase)
MAX AMPS (3 PHASE)
SM50EZ-12D WELL
208/240
500/660
2.4/2.75
N/A
ELECTRICAL SPECIFICATIONS
1. Follow General Operating Instructions on page 3.
1. Follow General Cleaning Instructions on page 3
NOTE: CUT-OUT SIZES ARE DIFFERENT FROM STANDARD APW HOT FOOD WELLS (HFW’S)
1.
Water fill is 3/8 (1.0) tubing connection on left back of left controls.
2.
Main drain is ¾ female NPT.
10.86
(27.6)
11.23
(28.5)
7.72
(19.6)
6.12
(15.6)
3.07
(7.8)
2
C
1 Water
Inlet
3.29
(8.4)
3.29
(8.4)
Drain
B
3.28
(8.3)
Cut-Out
Front Edge
A
6.00
(15.2)
10.00
(25.4) 12.50
(31.8)
4.74
(12.0)
2.00 (5.1) Minimum
From Counter Top
F
G
Control Cut-Out
D
E
Hot Food Well
Cut-Out
6.00 (15.2) Minimum
From Counter Edge
1. Follow general installation
instructions on page 3.
2. Make applicable Cut-Out per above
table.
Unit is designed for
installation in stainless steel tops.
Optional wood mounting kit available.
3. Apply putty tape to the underside
perimeter of the well rim outer edge.
4. Apply a 1/4" (.6) bead of silicone
sealant adjacent to the putty tape on
the well flange.
5. Drop well into opening from the top
and push down until entire
parameter of rim is flush with the
counter surface.
6. From below the counter surface
insert an 8" to 10" (20 to 25 cm) flat tip
screwdriver into the locking ring tab
slots and twist in a clockwise motion
to lock well in place.
7. Trim excess putty and sealant from
around well rim.
8. Mount control to front panel using
hardware. Maintain 4" (10.2)
clearance between well and front
panel.
9. Check nameplate for proper voltage.
Connect power.
10. Connect overflow tube on hot food
well to suitable tubing to handle
212°F water. Run to open drain.
Electrically connect units to
comply with local and NEC codes.
Note:
Note: