PEP Filters HMF2 User Manual
Page 14
![background image](/manuals/373129/14/background.png)
HMF2 Series Filter System
Operating & Maintenance Manual
PEP Filters
• 322 Rolling Hill Road • Mooresville, NC 28117 • 800-243-4583 •
www.pepfilters.com
14 of 19
Rev. 041204
Table 1 Inspection Chart
PART HMF
MODEL
Filter Tank
X
Valves & Linkage
X
Filter Inter-connection Piping
X
Pump Pre-strainer tank & basket
X
Pump
X
NEMA 4X Box (Auto only)
X
Filter Skid
X
Pressure gauge, air relief valves, & tees
X
Media (shipped Loose)
X
Table 2 Connection Sizes
System Water Backwash
City Water
Backwash
HMF2
Model
Pump Inlet
Filter Outlet
Waste Outlet
Inlet City Water
HMF
Inches/mm
12 2/50.8
1/25.4
1/25.4
1/25.4
18 2/50.8
2/50.8
2/50.8
2/50.8
24 2/50.8
2/50.8
2/50.8
2/50.8
30 2.5/63.5
2/50.8
2/50.8
2/50.8
36 2.5/63.5
3/76.2
3/76.2
3/76.2
42 3/76.2
3/76.2
3/76.2
3/76.2
48 3/76.2
3/76.2
3/76.2
3/76.2
Table 3 Filter Flow Rates
HMF2
Model
Forward Flow
gpm / lps
Minimum Backwash Flow Rate
gpm / lps
Maximum Backwash Flow Rate
gpm/lps
12 16/.96
12.8/.78
16/.96
18 35/2.2
28/1.8
35/2.2
24 63/3.8
47/3.0
63/3.8
30 98/6.2
74/4.6
98/6.2
36 141/4.0
107/6.7
141/4.0
42 192/13.0
144/9.1
192/13.0
48 251/15.8
188/11.9
251/15.8
Table 4 Electrical Requirements (1
φ, 60 Hz.)
PUMP HP/KW
Voltage 1
φ 60/50HZ
Full Load Current
(Amps)
1/0.75
110, 208, 240
16, 8.8, 8
2/1.5
115, 208, 230
24, 13.2, 12
3/2.25
208, 230
18.7, 17