PEP Filters BMF User Manual
Page 10

BMF Series Media Filter
Operating & Maintenance Manual
PEP Filters
• 322 Rolling Hill Road • Mooresville, NC 28117 • 800-243-4583 •
www.pepfilters.com
704-662-3133 (Outside USA) Page 10 of 14 Fax 704-662-3155
rev. 01/02
Table 4A Electrical Requirements – Three Phase, 50 Hz
Pump
HP / KW
Voltage (three phase)
50 Hz
Full Load Current
Amps
7.5 / 5.6
380, 415
11.5, 10.6
10 / 7.5
380, 415
15.1, 13.5
15 / 11.2
380, 415
23.7, 22.4
20 / 15
380, 415
31.1, 29.2
Table 5 Media Quantities for Non-Code BMF Filter Vessels
Optional 5 Micron Filtration
Filter Model
Under-drain
Support Gravel
Unigran 475
ft
3
Standard 10
Micron Filtration
Unigran 85
ft
3
Unigran 55
ft
3
Unigran 85
ft
3
BMF 54
18 34 17 17
BMF 60
23 42 21 21
BMF 66
29 51 25.5
25.5
BMF 72
37 64
32 32
BMF 78
47 75 37.5
37.5
BMF 84
56 87 44 44
BMF 90
68 100 50 50
BMF 96
81 136 68 68