beautypg.com

2198-a(rhem)英語, Led revolving warning light, Instruction manual – PATLITE RHEM User Manual

Page 2: Rhem・rkem, Rkem-12/24, Rhem-12/24

background image

2198-A

'12.05.NHI

Memo

.

Maintenance

To clean dome and body, wipe with water or glass cleaner soaked soft cloth.

Do not use thinner, benzine, gasoline or oil as these cause color change or deform the surface.

Do not lubricate oil to the motor and gear, it becomes a cause of motor failure.

Do not rotate the reflector by a hand directly.

Caution

Replace Dome

(

1)Turn off the power.

(2)

Rotate counterclockwise the dome and remove from body.

(3)

Rotate clockwise the new dome.

Please follow procedure mentioned below to replace to dome.

Maintenance procedure

・The replacement parts prepared. Please ask your local distributor for availability.

Dome ・Reflector ・O-ring

If you have question please contact us about other parts.

Replacement parts

Problems

Check point

Recovery method

Check the power line and fuse.

Check the switch,whem the

switch is installed.

Internal circuit may be damaged.

Request a repair.

Is the power supplied?

Reflector does not rotate and

LED is not lighting.

Reflector is rotateing.

LED is not lighting.

or

Reflector is not rotateing.

LED is lighting.

When the rotation was stopped forcibly

by hand,The rotation didn’t restart.

The protection circuit operated.

Turn on tne power supply again.

.

Before requesting service

Checking following list befor a repair request.
If the product is still not operaiting , contact us for repairs.
Please feel free to contact PATLITE Corporation with any questions concerning the product.
Report to us the lot number indicated on the nameplate at the time of inquiry.

8.

Specifications

mm)

.Dimensions

Model RHEM 】

Model RKEM 】

φ

100

3-M5

16

49

90

φ

100

3-M5

16

49

90

148

148

RHEM-M2

RHEM-12/24
RKEM-12/24

RKEM-M2

100~200V AC

12V DC

24V DC

240mm

AV / 0.5mm

2

Model: RHEM,RKEM】

Flashing cycle:120 Flashes per minute

Index of protection:IP23

Since rotation of gear system is used for this product,the sound of a gear can be heard.

3.0W

2.4W (12V)

3.4W (24V)

.Specifications

0.4kg

.

Option parts

Purpose

RHEM , RKEM

SZ-200ARubber gasket is available for wash-down application (meets IP 55 requirement)

Mounting pole & Bracket

Model

Part Name

Rubber Gasket

Wall Mount Bracket

SZ-007
SZ-008

SZ-30T
SZ-30L

SZ-200A

Model

Length of wire

Rated voltage

Power consumption

Mass

Wire type/Dia

We are not in a position to be responsible for damage and trouble caused by handling against caution

and warning described in this instruction manual.

Specifications may change without notice due to continual product improvement.

Caution

Loosed

Closed

Depending on the deteriorization of the O-ring for the body, any cracking or breaking
hinders the waterproof construction hand has to be replaced.
Regularly inspect the O-ring for cracking, breaking,stress,fatigue or any other
form of deterioration.

3.

Model No. configuration

RKEM-12/24

Rated voltage

12/24 :12/24V DC

M2 :100~200V AC

RHEM-12/24

Rated voltage

12/24 :12/24V DC

M2 :100~200V AC

.

Installation(Mounting)

Ask a specialist or an electric engineer for wiring construction. Otherwise electric shock, fire and fall may occur.

This product is indoor use only. Do not use in the place which get wet with water or rain.

The IP rate of this product is IP23. SZ-200A of an option is required at the place which gets wet with water.

When installing the unit in a high place, choose the place where a foothold can be secured for case in repairs.

Follow the precautions below to keep product's life from vibration.

(a) Do not install directly on vibrating or shock-producing equipment.

(b) Do not install on a column or a wall experiencing vibration.

Use rigid L brackets in order to prevent swing of the light caused by wind and other vibrations.

Please process mounting hole to attachment portion.

Please fix using attached nut set.

Machining of mounting hole is convenient if an attached paper pat tam is used.

.

Wiring procedure

Turn off the power before wiring connections.Othrewise an electric shock or a circuit breaks down.

Confirm the rated voltage of the product.

Do not mistake at wiring.Othrewise it causes a fire.

Refer to the following figure for wiring. Connecting wires must use the crimp-type terminal.

●I

nsert the fuse between power supply and this product.

Do not push or pull the lead wire at the time of wiring.

Attach the terminal cover to this product after wiring.

Ground the earth terminal about the Model RHEM/RKEM-M2 specification for the electric shock and the fire

accident prevention.

Caution

[※①]・

It is necessary to use the fuse certified by IEC60127 when using it as CE specification

[※②]・

Model RHEM/RKEM-M2 are to do a ground from the terminal of the body bottom part.

Max.8mm

φ

3mm

Terminal cover

Bottom view

Connecting wires must use the crimp-type terminal.

Use a crimp-type terminal with ring tongue and φ8mm or less in

external diameter.

Terminal should be fixed with attached screws (M3×6).

(Max. torque: 0.6N・m)

Refer to figure for the wire processing.

Supply RHEM/RKEM-12/24 type from Class2 circuit.

Use copper lead wire with the heat resistance 75 degrees C or more.

■Notes when using it as CE marking specification

To use the fuse certified by IEC60127

Double insulation processing to the exposed lead wire by the vinyl tube etc.

Caution

mounting hole

mounting surface

mounting foot

plain washer

spring washer

hex nut

example of mounting

φ

70

Mouting hole

3-φ6

120

120゜

25

R45

Terminal

Name plate

(Ref.)Wire exit

Mounting template

φ

70

Mouting hole

3-φ6

120

120゜

12゜

R14

Name plate

(Ref.)Wire exit

Without SZ-200A

With SZ-200A

Terminal

AC type does not have polarity

〔※①〕

Bottom view

Fuse

Power supply

N

L

Bottom view

Fuse

Power supply

RHEM-12/24 , RKEM-12/24

RHEM-M2 , RKEM-M2

(Suggested Fuse 3A

)

(Suggested Fuse 3A

)

〔※②〕

Earth terminal

Model RHEM/RKEM-M2 only

.

Parts name

1.

To operate this product safely, please observe the followings.

Do not put the flammable material, such as paper or cloth,
on this product while it is in operation. It may cause a

fire.

DANGER

Caution. risk of fire

Warning

Turn off the power at the time of wiring.Otherwise an electric shock or a circuit breaks down.

Do not use this product without dome or broken dome. It may cause electric shock.

Turn off the power for the electric shock and the burn prevention when you repair.

Ask a specialist or an electric engineer for wiring construction. Otherwise electric shock, fire and fall may occur.

Caution

Use it by the rated voltage.

Insert the fuse between power supply and this product.(Refer to 5.Wiring procedure)

Daily check is required to use it for the security or safety purpose.

Use auxiliary equipment in preparation for the tine of failure.

NOTES TO BE OBSERVED FOR SAFE OPERATION

Note to be followed to prevent any damage to the user and other personnel or to assets are as follows:

The indications for warning are divided into the following classes according to the degree of danger or

damage incurred when the warning is not taken into consideration and the product is not correctly used.

INSTRUCTION MANUAL

Model :

RHEM・RKEM

2198-A

Thank you for specifying for your application. Please read these instructions carefully before

you perform installation, maintenance and repair. Store this manual carefully for easy reference.

If you have any questions about this product, please contact PATLITE Corporation.

Warning

Indicates a potentially dangerous condition:

Failure to follow the instructions may lead to death or serious injury.

Indicates an imminently dangerous condition:

Failure to follow the instructions may lead to death or serious injury.

DANGER

Caution

Indicates a potentially dangerous condition:

Failure to follow the instructions may lead to slight injury or property damage.

A95100198

LED REVOLVING WARNING LIGHT

Bottom view

Power wires

Dome

Reflector

※Lot Number indicated

LED

Body

Name plate

Terminal cover

plain washer

spring washer

hex nut

nut set for mount

Attached paper pattern

Manual

※RHEM/RKEM-12/24 only

RHEM

This manual is related to the following products: