3. Part Names and Dimensions

Guard

Reflector

Bulb

Name Plate

Glass Globe

Acrylic Globe

Bracket

(Main Unit Cover)

Terminal Box Cover

4. Installation and Wiring

Caution

Accessory>

Mounting Dimension Drawing>

“Easy Lever”

Hex Wrench

External Connection Terminal

(Grounding Terminal)

Mounting Hole
4-φ9

Keylock

Hex Bolt for
Keylock

Terminal Box Cover

Globe Frame

(The line cable is

connected here)

Terminal

Terminal Setscrew

(M4)

Junction Box

• Request a special contractor to install and wire this product in accordance with the "User's factory explosion

prevention electricity equipment guide" from the Technology Institution of Industrial Safety.

• The terminal wiring is specified as the white wire is positive, and the black wire is negative for the DC12V, 24V

and 48V models. Verify the proper working voltage is connected.

• When wiring, use a conduit size of G3/4 and pressure-resistant metallic fittings (pressure-resistant sealing

cable glands). Ensure waterproofing has been done to the connection threads.

• For pressure-resistant metallic seals (pressure-resistant sealing cable glands), use our optional products

(officially approved) available separately. Pressure-resistant sealing cable glands from other companies
cannot be used.

• Avoid mounting this product in a location with direct vibrations and shock. If mounted where vibration is

intense, the lifespan of the electric bulb becomes shorter. In additon, the mounting location should be selected
where strong winds, vibration, etc. does not cause it to shake.

• When installing the product in a high place, choose a place where it is accessable by a ladder or scaffold to

perform inspection or maintenance.

• Only remove the terminal box cover when wiring, and do not scratch or damage the terminal box cover nor the

flat connection part of the bracket. If a crack, dent, etc. occurs, it loses the explosion proof capability.

• The cross section of the electric wire to be used, should be no less than 2.5 mm

2

.


1. Refer to the mounting dimension figure when making the mounting holes.
2. Use M8 nuts and bolts when installing.

1. Use the hexagon wrench supplied to remove the bolts to the terminal box cover (four places).
2. Please connect the wiring to the Terminal Buss with the "easy lever" supplied, and ensure the proper polarity is

connected. Connect the earth-ground wire to a grounding terminal.

- A small flat-head screwdriver or flathead screwdrivers indicated by the following manufacturers can be

substituted for the "Easy Lever".

Phoenix Contact Corporation Part Number: SZF0
WAGO Corporation Part Number: 210-120J

3. When the cable wiring within the terminal box is completed, fasten the terminal box coverwith the bolts, and use

the hexagon wrench to tighten the bolts, then secure the bracket. Do not remove the attached O-ring (rubber
packing).

5. Maintenance/Inspection

• Lamp or Dome replacement is to be done by an operator who received the proper training, and has been given

permission from a supervisor, and done after the power has been disconnected for 30 minutes or more.

• The bulb is to be replaced with an equivalent value indicated in this manual, or where it is indicated on the name

plate. If an electric bulb other than what is specified is used, an increase in the outer temperature could exceed
the rated value for the ignition point, causing an accidental explosion where the surrounding gas is present.

• Use this product within the ambient temperature limits and environment defined in this manual.
• Do not operate this product with the dome (body cover) removed.
• Do not apply oil to the motor or rubber belt. (The motor will stop rotating if oil enters it.)

Warning

Wiring Procedure>

Driver Insertion Slot

Wire Insertion Hole

Cabtyre Cable

Wire Conduit

Pressure-resistant Sealed Metal Fittings

(Pressure-resistant Sealed Cable Gland)

Sealing Fitting Bracket

Wire Insertion Hole

(Grounding Terminal)

Internal
Connection Terminal

Strip the wire.

Wire

Wire

Terminal Buss

“Easy Lever”

Lead
Wire

(Attention)

The cable wires should have a

cross-sectional area of no less than
2.5 mm

2

.

(Attention)

Water-proof the threading area for the electric wire

conduit and pressure-resistant seals.

Screw Thread: G3/4
Pitch: 1.81432

For DC Type

7. Specifications

(1) Cable Wire Connection

(2) Electric Wire Conduit Connection

(1) Push downward on the lever and insert the wire into

the slot from an angle, using the "easy lever" or

appropriate driver.

● Be careful when handling the "easy lever" it may be

sharp.

(2) Insert the stripped part of the electric wire fully into

the slot.

(3)

- Pull the "easy lever" out of the slot.
- Check that the electric wire is securly fixed to the

Terminal Buss.

- After connecting the electric wire into the terminal

box, store any extra electric wire inside the crevices.

Wiring Reference Diagram>

Some specifications may change for improvements, etc., without prior notice.

6.Options and Replacement Parts

Various replacement parts and options are available.

• Option (Example: cable line construction)

Pressure-resistant metal seals (Pressure-resistant Cable Gland)

1. Compatible Cable Phi7.4-Phi12

Code: A28220003

2. Compatible Cable Phi12-Phi16

Code: A28220002

• Replacement Parts

- Dome (Resin)

- Reflector

- Electric Bulb

- Accessories

Caution

• Maintenance and inspection should follow the "User's guide for factory explosion proof electric installation"

from the Technology Institution of Industrial Safety.

• Do not attempt to modify or change any parts.

• To extend the service life of this product, perform perodic inspections and pre-maintenance. Prior to

maintenance checks turn off the power.

• Wipe off any accumulated dirt of the resin dome and glass dome with a soft cloth moistened with water.

1. Wait 30 minutes or more after disconnecting the power supply.
2. Remove the hexagon bolts with the hexagon wrench accessory. The dome frame (body cover) is secured with a

bracket, and by firmly holding the dome frame (body cover) or guard and turning in a counterclockwise direction,
the globe frame (body cover) can be removed.

3. The resin globe can be removed by turning it counterclockwise.
4. To remove the electric bulb, push down and turn counterclockwise.
5. To install a new electric bulb, push down and turn in the clockwise direction.
6. Turn the resin globe clockwise to re-attach it.
7. Turn the globe frame (body cover) clockwise to re-attach it to the bracket. Do not remove the O-ring (rubber

packing) from the bracket.

8. Attach the key lock.
● If there are any questions regarding this product, please contact your nearest PATLITE representative.

Wire

Terminal No.

Polarity

Black

2

Negative

White

1

Positive

Product

RES-12A

RES-24A

RES-48A

RES-100A

RES-120A

RES-220A

RES-240A

Rated Voltage

DC12V

DC24V

DC48V

AC100 - 110V

AC115 - 120V

AC200 - 220V

AC230 - 240V

50/60 Hz

Operating Voltage Range

DC9.5 - 15V DC20 - 30V DC38 - 53V

AC100 - 110V

AC115 - 120V

AC200 - 220V

AC230 - 240V

Rated Current

0.9A

0.6A

0.3A

0.1A

0.1A

0.05A

0.05A

Flash Rate

170 rpm

150 rpm

170 rpm

Rotating Direction

Clockwise

Bulb Type

12V 10W

24V 10W

48V 10W

12V 10W

Base: BA15S Bulb: G18

Operating Temperature Range

-20

o

C to +55

o

C

-20

o

C to +60

o

C

Atmospheric Pressure

Atmospheric Pressure: 80 - 110kpa

Relative Humidity

Relative Humidity: 45 - 80%

Mounting Direction

Indoors: Upright, Sideways, Upside-down Outdoors: Upright

Protection Rating

IP65

Vibration Resistance

44.1m/s

2

(Passes JIS D 1601-1990 Level 4 Class 3/Type B)

Insulation Resistance

More than 1Mohm at DC500V between a power supply terminal and the chassis

Withstand Voltage

The following voltage is applied for 1 minute between a power supply terminal and

the chassis without breaking insulation.

AC 1,000V

AC 1,500V

Illumination

8000cd

5200cd

4800cd

3340cd

Spare Bulb

None

Mass

6.5kg

130

130

12

1

2

296

22 7

φ214