Blue-white, Installation guideline – Blue-White Flow Verification Sensor (FVS) User Manual
Page 2

Installation Guideline
Industries, Ltd.
Blue-White
Industries, Ltd.
®
A-100NV
Peristaltic Pump
C-1100V
Diaphragm Pump
C-1500NK
Diaphragm Pump
The Micro Flow FVS can be connected directly to many
Blue-White injector pumps (see table below). The sensor
will verify that chemical injection has actually occurred.
The pumps sophisticated electronics continuously monitor
the sensor. If chemical should fail to inject, the pump will
stop and an alarm relay will close - allowing for remote
alarm indication and/or initiation of a back-up injector
pump.
Recommended sensor mounting locations differ from
diaphragm pump to peristaltic pump.
Diaphragm pump installation; the sensor should be
mounted on the discharge (outlet) side of the pumphead.
The sensor can be mounted directly on the pumphead or
anywhere along the tubing on the discharge side of the
pump.
Peristaltic pump installation; the sensor should be
mounted on the suction (inlet) side of the pumphead.
Peristaltic
Suction side of
pump head
A-100NV
Peristaltic
Suction side of
pump head
A-100NA
Peristaltic
Suction side of
pump head
A-100NF
Diaphragm
Discharge side of
pump head
C-1100V
Diaphragm
Discharge side of
pump head
C-1100A
Diaphragm
Discharge side of
pump head
C-1100F
Diaphragm
Discharge side of
pump head
C-1500NK
Variable speed
Fixed speed
timer controlled
Fixed speed
timer controlled
Variable speed
Fixed speed
timer controlled
Fixed speed
timer controlled
Fixed speed
timer controlled
Blue-White FVS compatible metering pumps:
Pump Type
FVS Installation
Location
Pump
Series
Pump
Description
6 seconds
6 seconds
User programmable
(up to 256 seconds)
6 seconds
6 seconds
6 seconds
Pump Shut-
Down Time*
User programmable
(up to 256 seconds)
* Pump Shut-Down Time = If chemical should fail to inject in the amount
of time specified, the pump will automatically shut-down, also triggering
an alarm relay.
FVS
Page 1