Manual Speed Adjust

OFF

Manual Speed Adjust

Press START to run

Peristaltic Metering Pump

Industries, Ltd.

ProSeries

by Blue-White Ind.

d

Peristaltic Metering Pump

Industries, Ltd.

ProSeries

by Blue-White Ind.

d

Page 11

Flex-Pro

7.0

Pump Output Speed Adjustment

Press UP arrow to increase pump output. Press DOWN arrow to increase
pump output.

Pressing the START button
repeatedly will toggle the
display to indicate the
%SPEED, RPM, and Tube
Timer Hours.

Tip!

Manual Speed Adjust

GAL/DAY

228

Е

Й

ДИ

Displays current rotor direction

Manual Speed Adjust

RPM

62

Е

Й

ДИ

Manual Speed Adjust

%SPEED

70.8

Е

Й

ДИ

186

PUMP TUBE TIMER

Enter twice to reset

Current tube timer:

Hrs.

Tube Timer Displays
for 4 seconds.

- Contact Closure Input

Close: Stop Pump
Open: Stop Pump
Disable

Done

8.0

Contact Closure Input (Remote Start/Stop)

Used to remotely start and stop the pump using a close=stop or open=stop
signal. If the pump must start when the loop is open, then select “Close: Stop
Pump” option. Can be used with an external foot pedal, a PLC, contact closure,
or other similar external devices.

Default settings:

Disable

CC Input Range:

6 - 30 VDC
or
Dry Contact Closure (no voltage required)
[See section 5.1 for wire connections]

Navigate to Contact Input menu by holding the START button for 5 seconds.

Press UP or DOWN arrow to scroll through your options.

Press START to make a selection. The radio button (square box) is now filled in
next to your selection.

Press DOWN arrow to scroll down to Done selection. Then press START.

IMPORTANT: To begin operation, press the START button to place pump in
STANDBY. The display background will turn blue indicating the pump has been
stopped remotely. When the pump is started by the remote contact, the display
background will turn green.

IMPORTANT: If the Contact Closure Input is enabled, the pump will display
STANDBY if the pump has been stopped by the Remote Contact Closure.
Please use caution in this mode as the pump may Start at anytime. If you
must perform maintenance to the pump, Press STOP button.

When Contact Closure Input is enabled, the word Remote will always be
displayed on the lower left side of the display screen.

Manual Speed Adjust

Waiting for SIGNAL...

STANDBY

REMOTE

Manual Speed Adjust

GAL/DAY

228

Е

Й

ДИ

REMOTE

Signal stopped pump

Signal started pump