To clean the surface of the unit use a gentle detergent and damp cloth, and then wipe it dry with a
soft clean cloth.

Cleaning the filter

The air filter should be cleaned at least once every two weeks, to prevent it from becoming clogged
with dust/dirt. Open the air inlet grille on the back of the unit and take out the air filter. Clean the air
filter with gentle detergent in lukewarm water. The filter should be left to dry, out of direct sunlight.
Put the air filter into the inlet grill on the back of the unit; replace the components as they were

Troubleshooting

Problem

Possible Causes

Corrective Action

1. The unit does not start

when pressing on/off button

- Water full indicator lamp

blinks,

(“F”) and water tank is

full.

Drain the water from the water

tank.

- Room temperature is higher

than the set temperature.

Reset the temperature

- Room temperature is lower

than the setting temperature

Reset the temperature

2. Not cool enough

- The doors or windows are not

closed.

Make sure all the windows and

doors are closed.

- There are heat sources inside

the room.

Remove the heat sources if

possible

- Exhaust air hose is not

connected or blocked.

Connect or clean the exhaust

air hose.

- Temperature setting is too

high.

Reset the temperature

- Air inlet is blocked.

Clean the air inlet.

3. The unit is noisy/loud

- The ground is not level or not

flat enough

Place the unit on a flat, level

ground if possible

- The sound comes from the

flowing of the refrigerant inside

the air conditioner

It is normal.

4. E0 Code

- Room temperature sensor

failed

Replace room temperature

sensor (the unit can also work

without replacement.)

5. E2 Code

- Water tank full.

(“F”)

Please drain the water tank.