Cu 1 – 4 condensing units, Capacity data - heat pump unit – Airedale Condensing Units (CU) 3kW - 80kW User Manual
Page 6
![background image](/manuals/370962/6/background.png)
CU 1
– 4
Condensing Units
6
Condensing Units
Technical Manual : 904-020 v1.3.0 02_13
Capacity Data - Heat Pump Unit
Cooling
Duty
Mean Evaporating
Temperature
°C
Ambient
25°C
30°C
35°C
40°C
45°C
Output kW Input kW Output kW Input kW Output kW Input kW Output kW Input kW Output kW Input kW
CUH1
-5
2.62
0.90
2.45
1.04
2.30
1.19
2.13
1.33
1.96
1.47
0
3.11
0.95
2.92
1.08
2.73
1.23
2.55
1.37
2.35
1.51
5
3.70
0.98
3.50
1.12
3.30
1.26
3.10
1.41
2.90
1.55
10
4.32
1.02
4.11
1.15
3.90
1.28
3.67
1.44
3.44
1.59
CUH1.5
-5
3.57
1.27
3.35
1.47
3.14
1.68
2.91
1.87
2.68
2.08
0
4.25
1.31
4.02
1.52
3.79
1.71
3.55
1.92
3.31
2.13
5
5.05
1.38
4.79
1.58
4.51
1.78
4.24
1.99
3.97
2.19
10
5.90
1.44
5.62
1.63
5.33
1.81
5.02
2.04
4.70
2.25
CUHS2
-5
3.85
1.05
3.61
1.21
3.38
1.38
3.14
1.55
2.89
1.72
0
4.58
1.08
4.33
1.26
4.08
1.41
3.82
1.58
3.56
1.76
5
5.44
1.14
5.16
1.31
4.86
1.47
4.57
1.64
4.27
1.80
10
6.36
1.19
6.05
1.34
5.74
1.50
5.40
1.68
5.06
1.85
CUHS2.5S
-5
5.73
1.67
5.39
1.93
5.03
2.17
4.64
2.45
4.23
2.72
0
6.84
1.75
6.46
2.00
6.09
2.25
5.66
2.52
5.24
2.79
5
8.06
1.85
7.66
2.09
7.25
2.32
6.78
2.61
6.30
2.89
10
9.41
1.95
8.95
2.18
8.49
2.41
7.93
2.69
7.37
2.96
CUHS2.5T
-5
5.66
1.65
5.46
1.92
5.25
2.18
5.06
2.44
5.31
2.71
0
6.89
1.76
6.54
2.00
6.17
2.25
5.83
2.49
5.43
2.78
5
8.06
1.83
7.67
2.08
7.27
2.32
6.84
2.60
6.41
2.87
10
9.31
1.94
8.88
2.18
8.44
2.41
7.98
2.68
7.51
2.95
CUHS3
-5
6.71
2.04
6.36
2.34
6.01
2.64
5.67
2.95
5.28
3.30
0
7.95
2.18
7.55
2.44
7.14
2.70
6.71
3.01
6.28
3.39
5
9.30
2.28
8.83
2.58
8.37
2.84
7.89
3.17
7.36
3.48
10
10.75
2.41
10.24
2.68
9.72
2.97
9.17
3.28
8.63
3.59
CUHS3.5
-5
8.31
2.38
7.86
2.68
7.40
2.98
6.94
3.28
6.48
3.58
0
9.96
2.50
9.42
2.79
8.88
3.08
8.37
3.39
7.85
3.71
5
11.86
2.66
11.09
2.93
10.33
3.20
9.83
3.51
9.33
3.82
10
13.61
2.81
12.75
3.07
11.89
3.32
11.41
3.64
10.93
3.96
CUHS4
-5
10.14
2.40
9.46
2.86
8.81
3.32
8.20
3.79
8.20
3.79
0
11.94
2.52
11.27
2.99
10.61
3.45
9.91
3.91
9.39
4.43
5
13.96
2.75
13.25
3.20
12.53
3.64
11.88
4.10
11.28
4.61
10
16.27
2.99
15.52
3.42
14.76
3.84
13.93
4.27
13.08
4.80
1
Output kW refers to the compressor duty.
2
Input kW refers to the compressor input power only.
3
Cooling data for a cooling only unit.
Heating Duty
Outdoor
Air On
Mean Condensing Temperature
30°C
35°C
40°C
45°C
50°C
55°C
°C %RH
Output kW
Output kW
Output kW
Output kW
Output kW
Output kW
CUH1
5
85
3.81
3.76
3.70
3.72
3.70
3.51
7
85
4.02
3.95
3.90
3.91
3.75
3.63
10
80
4.29
4.22
4.16
4.16
4.15
4.11
CUH1.5
5
85
4.70
4.63
4.62
4.59
4.57
4.55
7
85
4.98
4.90
4.87
4.84
4.80
4.78
10
80
5.32
5.23
5.19
5.14
5.31
5.41
CUHS2
5
85
5.44
5.37
5.29
5.32
5.29
5.01
7
85
5.74
5.65
5.57
5.59
5.36
5.19
10
80
6.13
6.03
5.94
5.94
5.93
5.88
CUHS2.5S
5
85
8.14
8.02
7.99
7.95
7.91
7.87
7
85
8.63
8.49
8.43
8.38
8.31
8.27
10
80
9.19
9.04
8.99
8.93
8.87
8.72
CUHS2.5T
5
85
8.14
8.02
7.99
7.95
7.91
7.87
7
85
8.63
8.49
8.43
8.38
8.31
8.27
10
80
9.19
9.04
8.99
8.93
8.87
8.77
CUHS3
5
85
9.30
9.25
9.20
9.17
9.12
9.09
7
85
9.83
9.79
9.77
9.77
9.76
9.73
10
80
10.59
10.46
10.32
10.26
10.20
10.08
CUHS3.5
5
85
11.92
11.71
11.62
11.51
11.40
11.32
7
85
12.61
12.36
12.27
12.15
12.00
11.89
10
80
13.51
13.23
13.12
12.95
12.78
12.59
CUHS4
5
85
13.57
13.51
13.48
13.43
13.38
13.36
7
85
14.34
14.25
14.21
14.14
14.06
14.01
10
80
15.42
15.19
15.08
15.02
14.89
14.79
1
Output kW refers to the compressor duty.
2
Indoor ambient at 20°C.