Problem
Probable Cause
Try...
Blank display
Flow rate steadily reads
zero when there is flow
Flow rate intermittently
drops when there is flow
Jumpy reading
Replace battery pack (part #31126)
Reading will resume when flow increases
Reposition meter for full pipe
Note flow direction arrow, reverse meter
Reposition meter for full pipe or rotate to
avoid bubbles (see page 2)
Check for proper ground
Use external power source
(allows more flow averaging)
Dead battery
Flow is below cutoff (very low)
There is air in the meter
Meter is installed backward
There is air in the meter
Missing or incorrect ground wire
Pulsing flow
FLOW RANGE
TROUBLESHOOTING
4”
6”
8”
10”
Gal/Min Liter/Sec
Gal/Min Liter/Sec
Gal/Min Liter/Sec
Gal/Min Liter/Sec
12
45
32
120
60
230
95
360
500
1,890
1,200
4,550
2,200
8,330
3,500
13,250