Features and options, 2 specifications – Rola-Chem 554230 ORP Digital Controller User Manual
Page 6

2.2 Specifications
Display:
0 to 995 mV
Control:
400 to 900 mV
Factory default:
650 mV
Input Power
120 Volts AC, 50/60 HZ, 3 wire grounded power cord.
GFCI source required
Output Power
120 Volts AC, 50/60 HZ, 5 amps (fused)
Two 3-wire grounded power receptacles
Terminal strip for hardwire applications.
Displays:
ORP reading
– red digital LED
Flow/Power indicator
-green LED
Auto (operating mode) indicator -red LED
Alert indicator -red LED
Feed indicator -green LED
(NOTE- lamps flash during the feed time and are on constant
during the delay time of the feed cycle.)
O
perating Temperature: 40 to 120° F
Features and Options
+ORP setting
+ ORP feed/delay time + alert (high & low)
+ Flow switch input
+ Feed time out
+ fused output
2.3 Description of Controls
Modes: The controller has two modes of operation:
• ON/OFF/Set mode
• AUTO mode- operating
To move from one mode to another simply press the MODE button.
On/off /Set mode:
• To turn the controller “on”, press the MODE button.
Rola-Chem Digital Controller PN 554226 6/01/2012 Page: 6 of 12