QUICK START REFERENCE
Use this section for reference - please read all safety instructions and
appropriate manual sections for installation and operation instructions.
• Do NOT add chemicals to feeders until all start-up operations are completed.
• Manually adjust and balance pool/spa to acceptable levels and verify using DPD test kit
prior to start-up. Automation should be used to maintain chemical levels, not to balance
a pool/spa that is out of acceptable chemical ranges
On/Off:
- press the mode button to turn the unit on.
note: ‘FLOW’ light must illuminate.
- press and hold the mode button to turn the unit off.
“OFF” will be displayed in the windows
To Operate:
- press and release the mode button until the “AUTO” light is lit.
Unit will now operate in the factory preset ORP settings:
- Set level: 650 mV
- Feed times: 0.6 second feed with a 5 minute delay
- Limits/Alerts: 900 mV (High) & 100 mV (Low)
To Change Settings:
- Press and release the mode button –AUTO light off.
Note: Once the settings are changed, they will remain at
those settings until they are changed again.
- Set Level: press the Set Level button until the desired set point is reached.
- Feed Time: press the Feed Time button until the desired feed
time is reached.
The number represent the seconds of feed time
(all with 5 minute delays).
Range is 0.6 to 900 sec. (15 min.).
Constant feed is ‘con’.