7.0 Appendix

7.1 WATER CHEMISTRY RANGES

(These ranges are in accordance with suggested NSPI
Standards for swimming pools.)

pH: 7.4 -7.6

Alkalinity: Approx. 80-120 ppm ** (parts per million)
Higher levels may be acceptable in areas where it naturally
occurs in the local water supply.
Consult a pool professional in your area.
Cyanuric Acid:
0-50 ppm.

(Maintain at 30 ppm or less for best probe life.)*

TDS (Total Dissolved Solids): 300 - 2000 ppm
Calcium Hardness: 200-400 ppm
Free Chlorine:
1.0 - 3.0 ppm (> 700 millivolts ORP)

*20-30 ppm of cyanuric acid provides approx. 95% of the shielding effect for
chlorine.

**When using tri-chlor, recommended alkalinity is 95-125 ppm.

7.2 Typical System Installations

FILTER

**SAFETY FLOWSWITCH TO ENSURE
CIRCULATION TO CONTROL PROBES
AND INDICATOR THAT POOL
CIRCULATION IS OCCURRING.

*SAFETY FLOWSWITCH FOR

PROTECTION OF HEATER AND

TO ENSURE DILUTION OF
CHEMICAL INTO POOL.

*** OPTIONAL FILTER TO

HELP KEEP MANIFOLD

AND PROBES CLEAR OF

DEBRIS.

SYSTEM USING CHLORINE

EARTH
GROUND

MANUAL pH CONTROL

POOL
PUMP

WATER

FROM
POOL

EARTH
GROUND

*FLOWSWITCH

WATER
TO

POOL

ORP

CONTROLLER

PUMP

***FILTER

HEATER

**FLOWSWITCH

ELECTRICAL
OUTLET
CONTROLLED BY
CIRCULATION
SYSTEM

MANIFOLD

CHLORINE

Rola-Chem Digital Controller PN 554226 6/01/2012 Page: 12 of 12