beautypg.com

Camera connections – Revo REVDN700-2 User Manual

Page 6

background image

CAMERA CONNECTIONS

Connection Cable Description

COLOR

Description

RED AC24V/DC12V

WHITE AC24V/DC12V

BLUE RS485(-)

GREEN

RS485(+)

YELLOW

ALARM OUT

GRAY

DN EXT-IN

BLACK&WHITE

DN EXT-OUT

BLACK

GND

SKY BLUE

UTP+(Option)

PINK UTP-

(Option)


1) External Day/Night Control

Select Day/Night mode using external equipment, by connecting control lines to the
appropriate terminals.

z

DAY&NIGHT EXTERNAL INPUT

Switches the cameras D/N mode to either Day or Night based on the input
status. Refer to the diagram below. The cameras D/N mode must be set to
EXT for this to function.


z

DAY&NIGHT OUTPUT

The camera turns on an external IR LED Lamp by detecting the sensitivity on the AGC
level when the D&N mode is set "AUTO" on the OSD menu of the camera.

DA

B

DAY&NIGHT INPUT

Gray

GND

Black

Open contact: DAY

Close contact: NIGHT

GND

Black

Y&NIGHT OUTPUT

lack&White

● 0V : IR LED OFF (DAY)

● 5V/10mA : IR LED ON (NIGHT)



2) Alarm Out

-

TTL level

z

Motion detection signals are output through this port. (YELLOW AND GND)

z

Active state is configurable.


3) Power Input Terminal

z

RED & WHITE : These terminals accept 24VAC or 12 VDC. When using 12VDC

it is recommended to use a DC power supply that can support an inrush current
of 0.55A


4) Camera Control

z

GREEN : RS 485+

z

BLUE : RS 485-


5) UTP (Option)

z

Video signal through out the UTP Cable (SKY BLUE(+) & PINK(-))

6