Electrical installation, Connecting the power source, Caution – Precision Control Systems DryIR 6030 User Manual
Page 10: Making the interlock connections
Model 6030 Dry IR Drying System Instruction Manual
4. Insert the lamp lead wire into terminal blocks 1TB1-4 and 2TB1-4 and tighten the screw
terminal. Make sure that the terminal block is not tightened on the insulation of the wire.
5. When all of the lamps have been installed, check for electrical shorts to the heater’s
metal chassis and then replace the air deflectors and front cover.
Figure 3-1. Model 6030 Spring Clip and Terminal Block locations.
Electrical Installation
Connecting the Power Source
The Dry-IR Drying System must be connected to a dedicated 240V, 30-amp electrical circuit.
Secure the power cord and interlock circuit cable to the mounting arm with the supplied nylon
cable tie to keep it from being positioned under the heater module.
CAUTION!
• The heater module requires a dedicated power circuit.
Making the Interlock Connections
The purpose of the interlock line is to prevent the heater module from operating if the transport
is not running. This helps minimize the risk of fires if paper is under the heater module when the
transport comes to a halt. The Model 6030 may be ordered with a 24VAC relay, a 24VDC relay,
or a 120VAC relay installed.
6