Installing the Model 5620
Installing the Model 5620 Power Controller is a quick and simple process. It requires:
• Connecting the LOAD wires
• Selecting the proper output conditioning
• Connecting an external timer-start switch (optional)
• Connecting the LINE wires (main power)
1. Using a Phillips screwdriver, remove the four Phillips screws on the front of the 5620
and lift the top cover off.
2. With a straight edge screwdriver, loosen the screws on the two lower strain relief
clamps, located on the upper end of the 5620, enough to allow passage of the required
wiring. If using an external timer-start switch, loosen the screws on the upper strain
relief clamp as well.
Figure 3-1 Location of strain relief clamps and wiring access.