beautypg.com

Eneral, Eter, Pecifications – NOSHOK 1950 Series Compact Smart System 5-Digit Process Meter User Manual

Page 2

background image

1.

DISPLAY: 5 digit LCD 0.48" (12.2 mm) high digits

1950X-1 : Reflective LCD with full viewing angle
1950X-2 : Transmissive LCD with selectable red or green LED backlight,
viewing angle optimized. Display color change capability with output state
when using an output module.

2. POWER: Input voltage range is +9 to +28 VDC with short circuit and input

polarity protection. Must use an NOSHOK model PS3 or a Class 2 or SELV
rated power supply.

3. INPUT RANGES: Jumper Selectable

0 to 10 V, 0(4) to 20 mA, 0 to 50 mA

4. SENSOR INPUTS:

5. OVERRANGE RATINGS, PROTECTION & INDICATION:

9 to 28 VDC power circuit is not isolated from the signal circuit.
Input Overrange Indication: “

OLOL ”.

Input Underrange Indication: “

ULUL

”.

Display Overrange/Underrange Indication: “

.....

”/“-

.....

6. DISPLAY RESPONSE TIME: 500 msec min.
7. NORMAL MODE REJECTION: 60 dB 50/60 Hz
8. USER INPUT (USR): Programmable input. Connect USR terminal to USR

COMM to activate function. Internal 10K

:

pull-up resistor to +9 to 28 VDC.

Threshold Levels: V

IL

= 1.0 V max; V

IH

= 2.4 V min; V

MAX

= 28 VDC

Response Time: 5 msec typ.; 50 msec debounce (activation and release)

9. CONNECTIONS: Wire clamping screw terminals

Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 5 inch-lbs (0.565 N-m) max.

10. MEMORY: Nonvolatile E

2

PROM memory retains all programming

parameters and max/min values when power is removed.

11. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 requirements for

indoor use. Installation Category I, Pollution Degree 2. High impact plastic
case with clear viewing window. Panel gasket and mounting clip included.

12. ENVIRONMENTAL CONDITIONS:

Operating Temperature Range for 1950X-1 : -35 to 75°C
Operating Temperature Range for 1950X-1/1950X-2 depends on display

color and intensity level as per below

:

Storage Temperature: -35 to 85°C
Operating and Storage Humidity: 0 to 85% max. relative humidity (non-

condensing)

Vibration According to IEC 68-2-6: 5 to 500 Hz, in X, Y, Z direction for 1.5

hours, 5 g’s.

Shock According to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions.
Altitude: Up to 2000 meters

13. CERTIFICATIONS AND COMPLIANCES:

IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment

for measurement, control, and laboratory use, Part 1.

IP65 Enclosure rating (Face only), IEC 529

ELECTROMAGNETIC COMPATIBILITY

Emissions and Immunity to EN 61326: Electrical Equipment for
Measurement, Control and Laboratory use.

Notes:
1. Criterion A: Normal operation within specified limits.
Refer to EMC Installation Guidelines for additional information.

14. WEIGHT: 3.2 oz (100 g)

2

G

ENERAL

M

ETER

S

PECIFICATIONS

MODEL

NO.

DISPLAY COLOR

1950X-1

---

10 mA

40 mA

1950X-2

Red (max intensity)

85 mA

115 mA

1950X-2

Green (max intensity)

95 mA

125 mA

TEMPERATURE

1 & 2

-35 to 75°C

3

-35 to 70°C

4

-35 to 60°C

5

-35 to 50°C

1 & 2

-35 to 75°C

3

-35 to 65°C

5

4

-35 to 35°C

-35 to 50°C

INTENSITY LEVEL

Class A

EN 55011

Emissions

Emissions:

30 A/m

3 V/rms
Criterion A

Criterion A

EN 61000-4-8

EN 61000-4-6

RF conducted interference

1 kV L-L,

Criterion A

EN 61000-4-5

Surge

1 kV signal

2 kV power

Criterion A

EN 61000-4-4

Fast transients (burst)

2 kV L&N-E power

10 V/m

Criterion A

EN 61000-4-3

Electromagnetic RF fields

8 kV air discharge

4 kV contact discharge

Criterion A

EN 61000-4-2

Electrostatic discharge

Immunity to Industrial Locations:

Power frequency magnetic fields

Green Display

Red Display

INPUT CURRENT

@ 9 VDC WITHOUT

RELAY CARD

INPUT

RANGE

ACCURACY

@23 °C, less

than 85% RH

INPUT

IMPEDANCE

MAX INPUT

SIGNAL

RESOLUTION

TEMP.

COEFFICIENT

20 / 50 mA 0.1% of span

10

:

150 mA

1 μA

70 ppm / °C

10 VDC

0.1% of span

538 K

:

30 V

1 mV

70 ppm / °C

INPUT CURRENT

@ 9 VDC WITH