Sp 200, Applications, Scaling – Martel Electronics SP200 User Manual
Page 4: 3½ digit backlit lcd voltmeter module

SP 200
3½ Digit Backlit LCD Voltmeter Module
Specifications liable to change without prior warning
SP 200
Issue 3
October/2001
M.C.
Applies to SP 200/1
V+
V+
INH
INL
0V
GND
+
-
±200mV
RI
RO
Measuring a single ended input
voltage referenced to supply, i.e. the
input voltage and the meter's power
supply share the same 0V rail.
V+
V+
INH
INL
COM
0V
GND
+
-
±200mV
RI
RO
Measuring an input voltage referenced to
a floating supply, i.e. the input voltage
and the meter's power supply are isolated
from each other.
Measuring a 4-20mA loop current.
The meter's power supply must be isolated
from the 4-20mA current loop.
V+
V+
5k
220k
R
INH
INL
Set Zero
COM
0V
GND
I
+
I
-
4-20mA
RI
RO
R= Reading at 20mA
160
APPLICATIONS
Do not connect more than one meter to the same power supply if the meters cannot use the same signal
ground. Taking any input beyond the power supply rails will damage the meter.
Measuring supply voltage and current to a load.
Display DP1, DP2 or DP3 by connecting to GND, as required.
RI
RO
COM
INH
+5V
Load
Shunt
R
L
V+
V
A
S
1
INL
GND
Rs
7805
220nF
470nF
10uF
V
supply
I
Ra=1M
Rb=1k
S selects between voltage and current display.
1
Ra and Rb shown scaled for 200V .
Rs = 200mV (e.g. 0.1
for 2A range)
FSR
Ω
I
Page 4 of 4
Page 4 of 4
SCALING
Two resistors Ra and Rb
may be used to alter the
full scale reading (FSR) of
the meter - see table. The
meter will have to be re-
calibrated by adjusting the
calibration potentiometer
on the rear of the module.
FSR
Ra
Rb
2V
910k
100k
20V
1M
10k
Vin
200V
1M
1k
2000V*
1M
100R
200 A
0R
1k
2mA
0R
100R
in
20mA
0R
10R
200mA
0R
1R
µ
I
Voltage
Current
+
-
Ra
Rb
INH
11
12
Vin or in
I
INL
SP 200
Page 4 of 4
*Ensure that Ra is rated for high voltage use.