Martel Electronics DPM500 User Manual

Dpm 500, Dimensions, Connector sourcing guide

background image

DIMENSIONS

All dimensions in mm (inches)

Stock Number

Standard Meter

DPM 500

Backlit Single Rail Version

DPM 500S-BL

V

A

µ

CONNECTOR SOURCING GUIDE

METHOD

40 Pin DIL IC Socket

2

1

5

3

10

Rb

Ra

13 12

11

8

9

4

7

12.5mm (0.5“) Digit Height
Programmable Decimal Points
Auto-zero
Auto-polarity
200mV d.c. Full Scale Reading (F.S.R.)
Backlit Single Rail Version (DPM 500S-BL)
Annunciators

DPM 500

3½ Digit LCD Module

Specification

Min.

Typ.

Max.

Unit

Accuracy (overall error)*

0.05

0.1

% (±1 count)

Linearity

±1

count

Sample rate

3

sample/sec

Operating temperature range

0

50

°C

Temperature stability

100

ppm/°C

Supply

DPM 500

7.5

9

14

voltage

DPM 500S-BL

3.5

5

6.5

Supply current

DPM 500

150

DPM 500S-BL

250

Backlight

Voltage

5

V

(DPM 500S-BL)

Current

30

60

mA

Input leakage current (Vin = 0V)

1

10

pA

* To ensure maximum accuracy, re-calibrate periodically.

(not inc. backlighting)

SCALING

Two resistors Ra and Rb may be fitted in order to alter the

full scale reading (F.S.R.) of the meter - see table.

Meter will need re-calibration.

Required F.S.R.

Ra

Rb

2V

Note

910k

100k

20V

Note

1M

10k

200V

Note

1M

1k

2kV

Note

1M

100R

200 A

0R

1k

2mA

0R

100R

20mA

0R

10R

200mA

0R

1R

µ

V+

V

m

µ

A

M

K

XB3

E3

AB

POL

~

-

:

°F

°C

60.0 (2.36)

45.0 (1.77)

Display in TEST mode

REAR VIEW

30.0

(1.18)

16.0

(0.63)

1.1

(0.04)

8.2

(0.32)

a

a. DPM 500

6.7 (0.26)

DPM 500S-BL 12.1 (0.48)

b. 4.80 (0.19)

DPM 500S-BL ONLY

ON-BOARD LINKS

OPTIONAL SCALING

RESISTORS

4.0 (0.16)

15.2

(0.60)

b

24.8

(0.98)

52 (2.05)

1.87

(0.07)

0.5

(0.02)

2.54

(0.1)

5.0

(0.19)

8.5

(0.33)

-

-

+

+

1

1

7

7

12

12

15

14

21

21

40

40

Panel cut-out = 57 x 27 (2.24 x 1.06)

PANEL FITTING

Fit the bezel to the front of the panel and locate the meter into the bezel from behind. Alternatively the meter and bezel may be assembled before

fitting to the front of the panel but care must be taken not to use excessive force. Finally fit the window into the front of the bezel.

20

20

V+

TEST REF

HI REF LO

REF+

REF-

COM

IN

HI

IN

LO

BG

XDP

XG3

BP

DP1

DP2

DP3

V-

-5V

Hz

The DPM 500 uses advanced components and construction techniques to provide a uniquely compact unit. The meter is in a 40 pin

DIL integrated circuit format that can be plugged directly into a DIL socket or panel mounted using the snap in bezel. For single rail use,

the DPM 500S-BL features a built in negative rail generator, enabling the meter to measure a signal referenced to its own power supply

0V.

NOTE

Ensure link 10 is cut if fitting Ra.

-

+

° °

C F

µ

A

mV

k

MHz

SAFETY

To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. If voltages to the

measuring inputs do exceed 60Vdc, then fit scaling resistors externally to the module. The user must ensure that the incorporation of the

DPM into the user’s equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for

Measuring, Control and Laboratory Use).