Sp 100, Applications, Scaling – Martel Electronics SP100 User Manual

Page 4: 3½ digit led voltmeter module, Page 4 of 4

background image

Specifications liable to change without prior warning

SP 100

Issue 3

October/2001

M.C.

Applies to SP 100/1

APPLICATIONS

Do not connect more than one meter to the same power supply if the meters cannot use the same signal
ground. Taking any input beyond the power supply rails will damage the meter.

Page 4 of 4

Page 4 of 4

SCALING

Two resistors Ra and Rb
may be used to alter the
full scale reading (FSR) of
the meter - see table. The
meter will have to be re-
calibrated by adjusting the
calibration potentiometer
on the rear of the module.

FSR

Ra

Rb

2V

910k**

100k

20V

1M**

10k

Vin

200V

1M**

1k

2000V* 1M**

100R

200 A

0R

1k

2mA

0R

100R

in

20mA

0R

10R

200mA

0R

1R

µ

I

Voltage

Current

Page 4 of 4

* Ensure that Ra is rated for high voltage use.
** Ensure solder link LA is cut.

SP 100

3½ Digit LED Voltmeter Module

INH

INL

RI

RO

0V

0V

+

-

±200mV

V+

V+

DE

Measuring a single ended input
voltage referenced to supply, i.e. the
input voltage and the meter's power
supply share the same 0V rail.

INH

INL

COM

RI

RO

0V

0V

+

-

±200mV

V+

V+

DE

Measuring an input voltage referenced
to a floating supply, i.e. the input
voltage and the meter's power supply
are isolated from each other.

V+

V+

DE

5k

Set Zero

220k

R

INH

INL
COM

0V

0V

I

+

I-

4-20mA

current loop

RI

RO

Measuring a 4-20mA loop current.

The meter's power supply must be
isolated from the 4-20mA current
loop.

R= Reading at 20mA

160

RI

RO

COM

INH

+5V

Load

Shunt

R

L

V+

DE

V

A

S

1

INL

0V

Rs

7805

220nF

470nF

10uF

V

supply

Measuring supply voltage and current to a load.

Rs = 200mV

Display DP1, DP2 or DP3, by connecting to 0V, as required.

S selects between voltage and current measurement.

Ra and Rb shown scaled for 200V

1

FSR

(e.g. 0.1 / 400mW for 2A full scale)

I

FSR

I

Ra=1M

Rb=1k

INH

INL

COM

RI

RO

0V

0V

R

V+

V+

DE

Measuring current.
The meter's supply is isolated
from the current being measured.

R = 0.2

I

FSR

+

-

Ra

Rb

INH

Vin or in

I

INL

SP 100

LA

11

12

1

11

2

8

7

12

10

3

1

11

2

8

7

12

10

3

1

11

2

8

7

12

10

3

1

11

2

8

7

12

10

3

1

11

2

8

7

12

3

www.lascarelectronics.com

PO Box 770, Londonderry, NH 03053 1-800-821-0023
www.martelcorp.com