KYORITSU 4140 User Manual
Page 11
̶ 9 ̶
PHASEROTATION
Rated
Voltage
Remarks
50∼500V
45~65Hz
Correctphasesequence:displayed“1.2.3”and mark
Reversedphasesequence:displayed“3.2.1”and mark
Volts
Range
Display Range
Guaranteed
Voltage Range
Accuracy
500V
Volt:0 ∼ 525V
Frequency:40.0 ∼ 70.0Hz
25 ∼ 500Vrms
45 ∼ 65Hz
Volt:±(2%rdg+4dgt)
Frequency:±(0.5%rdg+2dgt)
Possiblenumberoftestswithfreshalkalinebatteries.
LOOP/PFC/PSC
:Approx.3000timesmin(ATT)
VOLT/PHASEROTATION :Approx.100H.
5.2 Operating error
LoopImpedance(EN61557-3)
FUNCTION
Operating range compliant
withEN61557-3operatingerror
Maximum percentage
operating error
L-PE
0.40~1999Ω
±30%
L-N/L-L
0.40~19.99Ω
The influencing variations used for calculating the operating error
are denoted as follows;
Temperature
: 0 ℃ and 35 ℃
Phaseangle
:Ataphaseangle0°to18°
Systemfrequency :49.5Hzto50.5Hz
System voltage
: 230V+10%-15%
Supplyvoltage
:6.8Vto10.35V
Harmonics
:5%of3rdharmonicat0°phaseangle
5%of5thharmonicat180°phaseangle
5%of7thharmonicat0°phaseangle
D.Cquantity
:0.5%ofthenominalvoltage