beautypg.com

Features, Specification – KYORITSU 1009 User Manual

Page 4

background image

― 14 ―

2. Features

This instrument, 1009, is a Digital Multimeter which designed for making measurement of the low-voltage equipment.

(1) Designed to international safety standards.

(6) Auto-ranging function

IEC 61010-1 overvoltage CAT.300V Pollution degree 2

(7) Frequency measurement function

IEC61010-031 (Requirements for the hand-held probe)

(8) DUTY measurement function

(2) REL function to check the difference of measured values

(Express Pulse width / Pulse period as a percentage)

(3) Auto power off function to save battery consumption

(9) Current function is protected by fuse

(4) Data hold function

(10) Instrument is protected from mechanical shock by holster.

(5) Diode and Continuity check function

3. Specification

● Measuring ranges and accuracy (23±5℃, under the 45%∼75%RH)

Ranges

DCV

400mV
4V
40V
400V
600V

0∼600V

(5 Autoranging)

Input impedance approx. 10MΩ

±0.6%rdg±4dgt

±1.0%rdg±4dgt

±1.6%rdg±4dgt (50 / 60Hz)

±2.0%rdg±4dgt (∼400Hz)
±1.3%rdg±4dgt (50 / 60Hz)

±1.7%rdg±4dgt (∼400Hz)
±1.6%rdg±4dgt (50 / 60Hz)

±2.0%rdg±4dgt (∼400Hz)

±2.0%rdg±4dgt

±1.0%rdg±4dgt

20∼399.9mV

Input impedance approx. 10MΩ

0∼600V

(4 Autoranging)

Input impedance approx. 10MΩ

0∼4000uA

(2 Autoranging)

0∼400mA

(2 Autoranging)

400mV
4V
40V
400V
600V
400uA
4000uA
40mA
400mA

ACV

DCA

Measuring range

Accuracy