ELECTRICAL CONNECTIONS

3

13

OPTIWAVE 7300 C

www.krohne.com

10/2010 - 4000176502 - AD IECEX OPTIWAVE7300 R02 en

3.2.2 How to close the terminal compartment

Ex d / Ex tD applications

• Attach the terminal compartment cover 2. Turn the terminal compartment cover carefully to

prevent damage to the thread and the gasket.

• Make sure that the terminal compartment cover is tight.
• Use a 3 mm Allen wrench to attach the cover stop 1.
• Make sure that the cover stop 1 screw is tight.

3.3 Terminal tightening capacity

The terminal tightening capacity for curent output terminals 1 and 2 is:

3.4 Equipotential bonding system

There is a terminal in the terminal compartment and another on the side of the converter
support pillar that can be used equipotential bonding conductors.

3.5 Ex ia / Ex iaD equipment

3.5.1 How to connect the electrical cables

Cable entries are supplied on customer demand. If you supply the cable entries, this part must
have a degree of ingress protection IP≥6x (IEC 60529).

• Use the electrical connection procedure in the Handbook.
• If possible, use galvanically-isolated equipment.
• Supply the Ex i / Ex iD equipment connected to the device. Use only certified intrinsically-safe

equipment.

• Connect only to separate certified, intrinsically-safe circuits. Make sure that the electrical

circuit characteristics are not more than the values that follow.

DANGER!
Ex d applications

Ex d applications

Ex d applications

Ex d applications
Make sure that the terminal compartment is correctly sealed. An explosion can cause death or
injury to personnel and/or damage to equipment. Obey the instructions that follow:

Type of wire

Terminal tightening capacity

[mm²]

[AWG]

Rigid

4

11

Flexible

2.5

13