Installation in the pipeline

Installation material not included, to be provided by customer (stud bolts,
nuts, gaskets, etc.)

Pipe flanges and operating pressure: refer to tables on ”limits” in Section 11.

Distance between pipe flanges
see fitting dimension ”a”, in Section 10 ”Dimensions and weights”.

L

max

L

min

Position of flanges
Install flowmeter in line with the pipe
axis. Pipe flange faces must be
parallel to each other,
max. permissible deviation:
L

max

- L

min

≤≤

0.5 mm

0.02”

Hard rubber liner
Please note the table on Page 4 for temperature limits of operation,
storage and transport.

Teflon

®

-PTFE liner

Install at the lowest point of the pipe run to avoid an excessive vacuum condition at
the meter. Do not remove or damage liner, which is formed around the flange edges.

Gaskets
Use gaskets suitable for the application and appropriate to the liner, not included
with flowmeter, to be provided by customer.

Grounding rings / protective rings (option)
On plastic pipes and internally coated metal pipelines, grounding rings must form the
conductive connection with the fluid. Refer to Section 7 ”Grounding for electrical connection.

Grounding ring No. 1

Grounding ring, protective ring No. 2 Grounding ring, protective ring No. 3

3 mm/0.12” thick

for flowmeters with Teflon

®

-PTFE

with cylindrical neck, to protect the liner

liner, solidly fitted to the flanges,

particularly at the inlet edge against

3 mm/0.12” thick

abrasive products, 3 mm/0.12” thick.
Length:

1

30 mm/1.18”, for

DN 300,

12“

100 mm/3.94”, for

DN 350,

14“

Teflon

®

is a registered trademark of Du Pont.