11 Limits

PLEASE NOTE!

The limits specified in the table for process temperature and operating pressure make allowance
for the tube liner and the flange standard. Refer also to the footnotes.

At ambient temperatures of +40 to +60 °C or +104 to +140 °F the product temperature
may not be higher than +60 °C or +140 °F.

Limits for pressure and temperature

Liner

Connection flange

Max. operating pressure in bar (psig)
at product temperature of ...

Meter size

Flange

Pressure rating S = Standard

standard

or flange class O = Option

20 °C (

68 °F)

40 °C (

105 °F)

60 °C (

140 °F)

90 °C (

194 °F)

PTFE

DN 10 – 20

DIN 2501

PN 40

S

40

(580)

40

(580)

40

(580)

40

(580)

3

/

8

” –

3

/

4

ANSI B 16.5

150 lb

S

19.0

*

(275)

*

18.9

*

(274)

*

17.9

*

(259)

*

17.1

*

(248)

*

300 lb

O

40

(580)

40

(580)

40

(580)

40

(580)

Hard
rubber

DN 25 – 50, DN 80

DIN 2501

PN 40

S

40

(580)

(580)

40

(580)

(580)

40

(580)

(580)

40

(580)

(580)

DN 65, DN 100 – 150

DIN 2501

PN 16

S

16

(230)

16

(230)

16

(230)

16

(230)

PN 40

O

40

(580)

40

(580)

40

(580)

40

(580)

DN 200 – 600

DIN 2501

PN 10

S

10

(150)

10

(150)

10

(150)

10

(150)

PN 16

O

16

(230)

16

(230)

16

(230)

16

(230)

PN 25

O

25

(360)

25

(360)

25

(360)

25

(360)

DN 700 – 1000

DIN 2501

PN 10

S

<10

**

.8

(<150)

**

<9.9

**

0

(<144)

**

<9.5

**

0

(<138)

**

on request

PN 16

O

<13.8

***

(<200)

***

<128

***

(<185)

***

<12.5

***

(<181)

***

on request

DN 1200

DIN 2501

PN 6/2.5

S/O

on request

on request

on request

on request

1” – 40”

ANSI B 16.5

150 lb

S

19.0

*

<

(275)

*

18.9

*

<

(274)

*

17.9

*

(259)

*

17.1

*

(248)

*

300 lb

O

40

(580)

40

(580)

40

(580)

40

(580)

14”

AWWA

B

S

0

6

0

(90)

0

6

0

(90)

0

6

0

(90)

0

6

0

(90)

D

O

10

(150)

10

(150)

10

(150)

10

(150)

*

**

with gaskets made of Neoprene or similar material

**

*

dependent on meter size

***

with gaskets made of Neoprene or similar material, dependent on meter size.

***

Note: Calculated operating pressures to DIN 2505 are much lower than the values in the table above.

Vacuum load

Liner

Meter size

Max. allowed vacuum load in mbar abs. (psia)
at product temperature of ...

DN mm

inch

20

°

C (

68

°

F)

40

°

C (

105

°

F)

60

°

C (

140

°

F)

80

°

C (

176

°

F)

PTFE

DN 10 – 20

3

/

8

” –

3

/

4

00

0

0.

(0)

00

0

0.

(0)

00

0

0.

(0)

00

0

0.

(0)

Hard

DN 25 – 300

0

1

12

250 (3.6)

250 (3.6)

400 (5.8)

400 (5.8)

rubber

DN 350 – 1000

14 – 40

500

(7.3)

500

(7.3)

600

(8.7)

600

(8.7)

DN 1200

48”

on request

on request

on request

on request