Service

6.1 Maintenance

For systems in hazardous areas, regular checks are required in order to maintain the proper
condition. The manufacturer recommends the following maintenance measures:

• Check the housing, the cable entry and the feed lines for corrosion and/or damage.
• Check the process connection and the piping connections for leakage.
• Check the entire sensor for dust deposits.

6.2 Dismantling

In order to prevent injury or material damage when replacing the sensor, always observe the
following points:

• Before dismantling the electrical connecting lines of the device, ensure that all the cables

leading to the sensor are de-energised themselves and to the reference potential of the
explosive area.

• All the relevant process pipes or containers must be depressurised before dismounting the

sensor.

• If the process pipes or the container contain products that are harmful to the environment or

to health, implement the appropriate safety measures before dismantling the sensor.

• Replace all the seals when reinstalling the device in the process pipe or container.

CAUTION!
Maintenance measures of a safety-relevant nature within the meaning of explosion protection
may only be carried out by the manufacturer, his authorised representative or under the
supervision of authorised inspectors.